Blood gas analysis as a surrogate for microhemodynamic monitoring in sepsis

被引:0
|
作者
Jingyi Wang [1 ,2 ]
Li Weng [2 ]
Jun Xu [1 ]
Bin Du [2 ]
机构
[1] Emergency Department,State Key Laboratory of Complex Severe and Rare Diseases,Peking Union Medical College Hospital,Chinese Academy of Medical Science and Peking Union Medical College
[2] Medical Intensive Care Unit,State Key Laboratory of Complex Severe and Rare Diseases,Peking Union Medical College Hospital,Peking Union Medical College and Chinese Academy of Medical
关键词
D O I
暂无
中图分类号
R459.7 [急症、急救处理];
学科分类号
100218 ;
摘要
BACKGROUND:Emergency patients with sepsis or septic shock are at high risk of death.Despite increasing attention to microhemodynamics,the clinical use of advanced microcirculatory assessment is limited due to its shortcomings.Since blood gas analysis is a widely used technique reflecting global oxygen supply and consumption,it may serve as a surrogate for microcirculation monitoring in septic treatment.METHODS:We performed a search using PubMed,Web of Science,and Google scholar.The studies and reviews that were most relevant to septic microcirculatory dysfunctions and blood gas parameters were identified and included.RESULTS:Based on the pathophysiology of oxygen metabolism,the included articles provided a general overview of employing blood gas analysis and its derived set of indicators for microhemodynamic monitoring in septic care.Notwithstanding flaws,several parameters are linked to changes in the microcirculation.A comprehensive interpretation of blood gas parameters can be used in order to achieve hemodynamic optimization in septic patients.CONCLUSION:Blood gas analysis in combination with clinical performance is a reliable alternative for microcirculatory assessments.A deep understanding of oxygen metabolism in septic settings may help emergency physicians to better use blood gas analysis in the evaluation and treatment of sepsis and septic shock.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 50 条
  • [1] Blood gas analysis as a surrogate for microhemodynamic monitoring in sepsis
    Jingyi Wang
    Li Weng
    Jun Xu
    Bin Du
    World Journal of Emergency Medicine, 2023, (06) : 421 - 427
  • [2] Blood gas analysis as a surrogate for microhemodynamic monitoring in sepsis
    Wang, Jingyi
    Weng, Li
    Xu, Jun
    Du, Bin
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2023, 14 (06) : 421 - 427
  • [3] Value of blood gas analysis and immunological indicators in early diagnosis and treatment monitoring of children with severe pneumonia and sepsis
    Shao, Chengliang
    Yang, Yanhua
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (10): : 6899 - 6905
  • [4] Microhemodynamic aberrations created by transfusion of stored blood
    Yalcin, Ozlem
    Ortiz, Daniel
    Tsai, Amy G.
    Johnson, Paul C.
    Cabrales, Pedro
    TRANSFUSION, 2014, 54 (04) : 1015 - 1027
  • [6] Point-of-Care-Monitoring: Blood gas analysis
    Bickenbach, Johannes
    Marx, Gernot
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2010, 45 (11-12): : 722 - 729
  • [7] Blood gas monitoring
    Zimmerman, JL
    Dellinger, RP
    CRITICAL CARE CLINICS, 1996, 12 (04) : 865 - +
  • [8] Blood-gas monitoring
    Terzi, R. G. G.
    Anaesthesia, Pain, Intensive Care and Emergency Medicine, 2005, : 471 - 491
  • [9] The BpTRU Automated Blood Pressure Device: A Surrogate for Ambulatory Blood Pressure Monitoring?
    Andrea, Lalonde E. S.
    Luc, Trudeau
    Christina, Holcroft
    Vicky, Tagalakis
    Ernesto, Schiffrin L.
    JOURNAL OF CLINICAL HYPERTENSION, 2013, 15
  • [10] Sepsis-Associated Acute Kidney Injury: Macrohemodynamic and Microhemodynamic Alterations in the Renal Circulation
    Prowle, John R.
    Bellomo, Rinaldo
    SEMINARS IN NEPHROLOGY, 2015, 35 (01) : 64 - 74