DIRECT DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ZWITTERIONIC MICELLAR MOBILE-PHASE - COMPARISON WITH AN ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE

被引:22
|
作者
HABEL, D
GUERMOUCHE, S
GUERMOUCHE, MH
机构
关键词
THEOPHYLLINE; DIRECT INJECTION; PLASMA; MICELLAR LIQUID CHROMATOGRAPHY; ZWITTERIONIC MOBILE PHASE;
D O I
10.1039/an9931801511
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatographic procedure is reported for the direct determination of theophylline in human serum. It includes the use of a micellar zwitterionic mobile phase [10(-3) mol l(-1) 3-(dimethyldodecylammonio) propanesulfonate (also known as C-12 DAPS)-propanol (97 + 3, v/v) and a mu Bondapak phenyl column. Detection is based on ultraviolet absorption at a wavelength of 273 nm. After dilution with the mobile phase, the serum is injected into the chromatography; no solvent extraction or deproteinization is performed. The linearity of the method described was excellent over the range 0.5-20 mg l(-1). The within-run precision was better than 2%, and the recovery of the theophylline approached 98%. Two hundred direct injections of serum samples did not affect the column life. The total analysis time, including chromatography, was approximately 15 min. As little as 0.5 mg l(-1) of theophylline could be detected, and the results were in good agreement with those of an enzyme multiplied immunoassay technique.
引用
收藏
页码:1511 / 1513
页数:3
相关论文
共 50 条
  • [1] DETERMINATION OF THEOPHYLLINE IN PLASMA - COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AN ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE
    EPPEL, ML
    OLIVER, JS
    SMITH, H
    MACKAY, A
    RAMSAY, LE
    ANALYST, 1978, 103 (1231) : 1061 - 1065
  • [2] COMPARISON OF SERUM THEOPHYLLINE CONCENTRATIONS MEASURED BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY AND QUANTITATIVE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE
    SHEEN, AE
    SLY, RM
    HITE, S
    GIBLIN, VR
    HEBERT, M
    ANNALS OF ALLERGY, 1979, 42 (02): : 77 - 79
  • [3] EVALUATION OF AN ENZYME IMMUNOCHROMATOGRAPHY METHOD FOR CARBAMAZEPINE - A COMPARISON WITH ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE, FLUORESCENCE POLARIZATION IMMUNOASSAY, AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OLES, KS
    PENRY, JK
    DYER, RD
    THERAPEUTIC DRUG MONITORING, 1989, 11 (04) : 471 - 476
  • [4] COMPARISON OF THEOPHYLLINE MEASUREMENTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ENZYME IMMUNOASSAY
    RYDER, KW
    OEI, TO
    GLICK, MR
    JIMERSON, JC
    KELLOGG, TL
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1057 - 1057
  • [5] Comparison of high-performance liquid chromatography and enzyme-multiplied immunoassay technique to monitor mycophenolic acid in paediatric renal recipients
    Sabine Irtan
    Said Azougagh
    Caroline Monchaud
    Michel Popon
    Véronique Baudouin
    Évelyne Jacqz-Aigrain
    Pediatric Nephrology, 2008, 23 : 1859 - 1865
  • [6] COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AN ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE FOR THE ANALYSIS OF SERUM PROCAINAMIDE AND N-ACETYLPROCAINAMIDE
    GALLAHER, C
    HENDERSON, GL
    LOW, RI
    AMSTERDAM, EA
    MASON, DT
    JOURNAL OF CHROMATOGRAPHY, 1980, 181 (3-4): : 490 - 496
  • [7] Comparison of high-performance liquid chromatography and enzyme-multiplied immunoassay technique to monitor mycophenolic acid in paediatric renal recipients
    Irtan, Sabine
    Azougagh, Said
    Monchaud, Caroline
    Popon, Michel
    Baudouin, Veronique
    Jacqz-Aigrain, Evelyne
    PEDIATRIC NEPHROLOGY, 2008, 23 (10) : 1859 - 1865
  • [8] QUINIDINE ASSAYS - ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE VS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LEHMANN, CR
    BORAN, KJ
    KRUYER, WB
    VANREET, RE
    PIERSON, WP
    MELIKIAN, AP
    WRIGHT, GJ
    DRUG INTELLIGENCE & CLINICAL PHARMACY, 1985, 19 (06): : 460 - 460
  • [9] COMPARISON OF PHENYTOIN AND CARBAMAZEPINE SERUM CONCENTRATIONS MEASURED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, THE STANDARD TDX ASSAY, THE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE, AND A NEW PATIENT-SIDE IMMUNOASSAY CARTRIDGE SYSTEM
    RAMBECK, B
    MAY, TW
    JURGENS, U
    BLANKENHORN, V
    JURGES, U
    KORNMERKER, E
    THERAPEUTIC DRUG MONITORING, 1994, 16 (06) : 608 - 612
  • [10] DETERMINATION OF INORGANIC ANIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A MICELLAR MOBILE PHASE
    MULLINS, FGP
    KIRKBRIGHT, GF
    ANALYST, 1984, 109 (09) : 1217 - 1221