DETERMINATION OF TRACE NON RARE-EARTH ELEMENTS IN HIGH-PURITY RARE-EARTH-OXIDES BY ICP-AES WITH MICROCOLUMN PRECONCENTRATION IN A FLOW-INJECTION SYSTEM

被引:0
|
作者
JI, HN [1 ]
LIAO, ZH [1 ]
JIANG, ZC [1 ]
XIE, J [1 ]
机构
[1] WUHAN UNIV,DEPT CHEM,WUHAN 430072,PEOPLES R CHINA
关键词
FLOW INJECTION; ICP-AES; ACTIVE CARBON SILICA GEL; SODIUM DIETHYLDITHIOCARBAMATE; STOP-FLOW TECHNIQUE; MICROCOLUMN PRECONCENTRATION; HIGH PURITY EU2O3;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new-method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate, reagent concentration, length of reaction coil, eluent acidity, etc. were optimized. In the buffer solution of NH3 . H2O/NH4Cl at pH 4.6, Al, Cr, Cu, Fe, Pb, V and Zn can be preconcentrated and then eluted with 4.5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8.1 similar to 12.6 With detection limits of mu g/mL level, and the RSD with metals at mu g/g level were 2.3 similar to 5.0% (n = 7). The method proposed can reduce the matrix interference effectively, and has been applied to the determination of non-rare earth metals at mu g/g level in high purity Eu2O3 With satisfactory results.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [1] Determination of Trace Non Rare Earth Elements in High Purity Rare Earth Oxides by ICP-AES with Microcolumn Preconcentration in a Flow Injection System
    吉红念
    廖振环
    江祖成
    谢金娥
    JOURNAL OF RARE EARTHS, 1995, (02) : 119 - 124
  • [2] DETERMINATION OF TRACE RARE-EARTH IMPURITIES IN HIGH-PURITY RARE-EARTH-OXIDES BY X-RAY-FLUORESCENCE SPECTROMETRY
    CHANDOLA, LC
    DESHPANDE, SS
    DIXIT, RM
    KAPOOR, SK
    KHANNA, PP
    MACHADO, IJ
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1991, 29 (06) : 433 - 437
  • [3] DETERMINATION OF TRACE AMOUNT OF 14 RARE-EARTH IMPURITIES IN HIGH-PURITY YTTRIUM-OXIDE WITH ICP-AES
    YANG, JF
    ZENG, XJ
    HUANG, BL
    ACTA CHIMICA SINICA, 1990, 48 (09) : 903 - 908
  • [4] PRODUCTION OF RARE-EARTH-OXIDES OF HIGH-PURITY
    ZHENG, ZY
    LING, DR
    SUN, Y
    JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) : 131 - 135
  • [5] SPECTROGRAPHIC DETERMINATION OF TRACE RARE-EARTH ELEMENTS IN HIGH-PURITY THORIUM
    CHANG, CC
    SHIH, JS
    CHANG, CT
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1974, 270 (03): : 187 - 190
  • [7] Determination of trace amounts of rare earth elements by ETV-ICP-AES combined with microcolumn separation/preconcentration
    Xiong, HC
    Hu, B
    Huang, WH
    Peng, TY
    Chen, SZ
    Jiang, ZC
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (11): : 1647 - 1650
  • [8] AN ICP-AES METHOD FOR THE DETERMINATION OF HEAVY RARE-EARTH ELEMENTS (EU-LU) IN HIGH-PURITY YTTRIUM-OXIDE
    MARATHE, SM
    BISWAS, SS
    PATIL, PB
    MURTY, PS
    MIKROCHIMICA ACTA, 1992, 109 (5-6) : 261 - 268
  • [9] Determination of Rare-earth elements in Titanium Matrix Composites by ICP-AES
    Pang Xiao-hui
    Gao Song
    Gao Shuai
    Zhang Yan
    ADVANCES IN CHEMICAL, MATERIAL AND METALLURGICAL ENGINEERING, PTS 1-5, 2013, 634-638 : 2119 - 2124
  • [10] APPLICATION OF ICP-AES TO THE DETERMINATION OF RARE-EARTH ELEMENTS IN PHOSPHATE SAMPLES
    EID, MA
    BROEKAERT, JAC
    TSCHOPEL, P
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2): : 107 - 112