TISSUE-RESPONSE TO INTRAPERITONEAL IMPLANTS OF POLYETHYLENE OXIDE-MODIFIED POLYETHYLENE TEREPHTHALATE

被引:28
|
作者
DESAI, NP [1 ]
HUBBELL, JA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM ENGN,AUSTIN,TX 78712
关键词
POLYETHYLENE OXIDE; POLYETHYLENE TEREPHTHALATE; SURFACE TREATMENT; ADHESION;
D O I
10.1016/0142-9612(92)90101-S
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyethylene terephthalate films surface modified with polyethylene oxide of mol wt 18 500 g/mol (18.5 k) by a previously described technique, were implanted in the peritoneal cavity of mice, along with their respective untreated controls, for period of 1-28 d. The implants were retrieved and examined for tissue reactivity and cellular adherence. The control polyethylene terephthalate surfaces showed an initial inflammatory reaction followed by an extensive fibrotic response with a mean thickness of 60-mu-m at 28 d. By contrast, polyethylene oxide-modified polyethylene terephthalate showed only a mild inflammatory response and no fibrotic encapsulation throughout the implantation period; at 28 d a cellular monolayer was observed. Apparently either the polyethylene oxide-modified surface was stimulating less inflammation, which was in turn stimulating less fibroblastic overgrowth, or the cellular adhesion to the polyethylene oxide-modified surface was too weak to support cellular multilayers.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 50 条
  • [1] CHARACTERISTICS OF THE TISSUE-RESPONSE TO MEDPOR POROUS POLYETHYLENE IMPLANTS IN THE HUMAN FACIAL SKELETON
    WELLISZ, T
    KANEL, G
    ANOOSHIAN, RV
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1993, 3 (03) : 223 - 235
  • [2] BIOLOGICAL RESPONSES TO POLYETHYLENE OXIDE MODIFIED POLYETHYLENE TEREPHTHALATE SURFACES
    DESAI, NP
    HUBBELL, JA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 829 - 843
  • [3] ELECTRON-TRANSFER REACTION OF POLYETHYLENE OXIDE-MODIFIED MYOGLOBIN IN POLYETHYLENE OXIDE OLIGOMERS
    OHNO, H
    TSUKUDA, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 341 (1-2): : 137 - 149
  • [4] THE TISSUE-RESPONSE TO HIGH-DENSITY POLYETHYLENE PARTICLES
    RUSHTON, N
    RAE, T
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (03): : 383 - 383
  • [5] EFFECT OF INFECTIONS ON THE DEGRADATION OF POLYETHYLENE TEREPHTHALATE IMPLANTS
    GUMARGALIEVA, KZ
    MOISEEV, YV
    DAUROVA, TT
    VORONKOVA, OS
    BIOMATERIALS, 1982, 3 (03) : 177 - 180
  • [6] TISSUE-RESPONSE TO PERCUTANEOUS IMPLANTS IN RABBITS
    JANSEN, JA
    VANDERWAERDEN, JPCM
    VANDERLUBBE, HBM
    DEGROOT, K
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (03): : 295 - 307
  • [7] DYNAMIC FATIGUE OF MODIFIED POLYETHYLENE TEREPHTHALATE
    MATUSEVICH, PA
    TATARINOV, BA
    MATUSEVICH, YI
    LEVDANSKII, VA
    KRUL, LP
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1982, 55 (12): : 2460 - 2462
  • [8] Polyethylene terephthalate graft copolymers acting as an interfacial modifier in rubber modified polyethylene terephthalate compounds
    Bourland, Larry G.
    JOURNAL OF PLASTIC FILM & SHEETING, 2015, 31 (04) : 363 - 378
  • [9] BIODEGRADABLE ELASTOMERIC BIOMATERIALS - POLYETHYLENE OXIDE-POLYETHYLENE TEREPHTHALATE COPOLYMERS
    REED, AM
    GILDING, DK
    WILSON, J
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1977, 23 : 109 - 115
  • [10] DEFORMATION OF POLYETHYLENE OXIDE, NYLON-11 AND POLYETHYLENE TEREPHTHALATE BY ROLLING
    GEZOVICH, DM
    GEIL, PH
    JOURNAL OF MATERIALS SCIENCE, 1971, 6 (06) : 531 - &