Customized Acetabular Components in Revision hip Arthroplasty

被引:3
|
作者
Kavalersky, G. M. [1 ]
Murylev, V. Yu. [1 ,2 ]
Rukin, Y. A. [1 ]
Lychagin, A. V. [1 ]
Elizarov, P. M. [1 ,2 ]
机构
[1] IM Sechenov First Moscow State Med Univ, 8-2 Ul Trubetskaya, Moscow 119991, Russia
[2] SP Botkin Moscow City Clin Hosp, 5,2nd Botkinskiy Proezd, Moscow 125284, Russia
来源
TRAVMATOLOGIYA I ORTOPEDIYA ROSSII | 2016年 / 22卷 / 04期
关键词
3D printing in orthopaedic surgery; customized tri-flange acetabular component; pelvic discontinuity; revision hip arthroplasty;
D O I
10.21823/2311-2905-2016-22-4-114-121
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3 +/- 19,4 years (38 to 78 years). Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3 +/- 2,5 months (3 to 8 months). The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery - 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component's flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be widened to various orthopaedic centres and will undoubtedly improve the quality of treatment for such patients.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [1] Constrained acetabular components in complex revision total hip arthroplasty
    McCarthy, JC
    Lee, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 210 - 215
  • [2] Re-revision of failed revision Total Hip Arthroplasty acetabular components
    Lim, Seung-Jae
    Lee, Young-Suk
    Lim, Byung-Ho
    Park, Youn-Soo
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 357 - 364
  • [3] Use of custom triflanged acetabular components in revision total hip arthroplasty
    Holt, GE
    Dennis, DA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 209 - 214
  • [4] Fixation, Survival, and Dislocation of Jumbo Acetabular Components in Revision Hip Arthroplasty
    Lachiewicz, Paul E.
    Soileau, Elizabeth S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (06): : 543 - 548
  • [5] Revision arthroplasty of the hip - Acetabular component
    Gollwitzer, H.
    von Eisenhart-Rothe, R.
    Holzapfel, B. M.
    Gradinger, R.
    CHIRURG, 2010, 81 (04): : 284 - +
  • [6] Outcomes of Modular Dual Mobility Acetabular Components in Revision Total Hip Arthroplasty
    Sutter, E. Grant
    McClellan, Taylor R.
    Attarian, David E.
    Bolognesi, Michael P.
    Lachiewicz, Paul F.
    Wellman, Samuel S.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : S220 - S224
  • [7] Bilobed oblong porous coated acetabular components in revision total hip arthroplasty
    Berry, DJ
    Sutherland, CJ
    Trousdale, RT
    Colwell, CW
    Chandler, HP
    Ayres, D
    Yashar, AA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (371) : 154 - 160
  • [8] Constrained Acetabular Components Used in Revision Total Hip Arthroplasty: A Registry Analysis
    Lewis, Peter L.
    Graves, Stephen E.
    de Steiger, Richard N.
    Cuthbert, Alana R.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3102 - 3107
  • [9] Fate of cementless acetabular components retained during revision total hip arthroplasty
    Beaulé, PE
    LeDuff, MJ
    Dorey, FJ
    Amstutz, HC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2288 - 2293
  • [10] Removal of well-fixed, cementless, acetabular components in revision hip arthroplasty
    Mitchell, PA
    Masri, BA
    Garbuz, DS
    Greidanus, NV
    Wilson, D
    Duncan, CP
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (07): : 949 - 952