LUNG - SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE

被引:125
|
作者
VOCK, P [1 ]
SOUCEK, M [1 ]
DAEPP, M [1 ]
KALENDER, WA [1 ]
机构
[1] SIEMENS AG,MED SYST,W-8520 ERLANGEN,GERMANY
关键词
Computed tomography (CT); image quality; technology; Lung; CT; 60.1211;
D O I
10.1148/radiology.176.3.2389050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors adapted the transport system of a computed tomographic (CT) scanner with continuous rotation capability to examine complete lung subvolumes during a single breath hold. Twenty-four adult patients underwent scanning with up to 12 continuous 1-second rotations, and data acquisition was synchronized with longitudinal patient motion at one section thickness per second. Interpolated planar raw data were obtained retrospectively from any level within the volume, and these afforded high-quality images that were comparable to standard images. Solitary pulmo-nary nodules were not omitted, their centers could always be depicted, and secondary reformations as well as three-dimensional reconstructions were obtained easily. The authors conclude that spiral volumetric CT, by completely surveying a subvolume of the lung, is an attractive new application of CT.
引用
收藏
页码:864 / 867
页数:4
相关论文
共 50 条
  • [1] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [2] CENTRAL PULMONARY THROMBOEMBOLISM - DIAGNOSIS WITH SPIRAL VOLUMETRIC CT WITH THE SINGLE-BREATH-HOLD TECHNIQUE - COMPARISON WITH PULMONARY ANGIOGRAPHY
    REMYJARDIN, M
    REMY, J
    WATTINNE, L
    GIRAUD, F
    RADIOLOGY, 1992, 185 (02) : 381 - 387
  • [3] DIAGNOSIS OF CENTRAL PULMONARY THROMBOEMBOLISM BY USING SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE - COMPARISON WITH PULMONARY ANGIOGRAPHY
    REMY, M
    REMY, J
    WATTINNE, L
    GIRAUD, F
    RADIOLOGY, 1992, 185 : 131 - 131
  • [4] Implementation of single-breath-hold cone beam CT guided hypofraction radiotherapy for lung cancer
    Renming Zhong
    Jin Wang
    Lin Zhou
    Feng Xu
    Li Liu
    Jidan Zhou
    Xiaoqin Jiang
    Nianyong Chen
    Sen Bai
    You Lu
    Radiation Oncology, 9
  • [5] Implementation of single-breath-hold cone beam CT guided hypofraction radiotherapy for lung cancer
    Zhong, Renming
    Wang, Jin
    Zhou, Lin
    Xu, Feng
    Liu, Li
    Zhou, Jidan
    Jiang, Xiaoqin
    Chen, Nianyong
    Bai, Sen
    Lu, You
    RADIATION ONCOLOGY, 2014, 9
  • [6] Screening helical CT in the lung: Application of low-dose and single-breath-hold scanning
    Itoh, S
    Ikeda, M
    Satake, H
    Ishigaki, T
    RADIOLOGY, 1996, 201 : 361 - 361
  • [7] Single-breath-hold photoacoustic computed tomography of the breast
    Lin, Li
    Hu, Peng
    Shi, Junhui
    Appleton, Catherine M.
    Maslov, Konstantin
    Li, Lei
    Zhang, Ruiying
    Wang, Lihong, V
    NATURE COMMUNICATIONS, 2018, 9
  • [8] Single-breath-hold photoacoustic computed tomography of the breast
    Li Lin
    Peng Hu
    Junhui Shi
    Catherine M. Appleton
    Konstantin Maslov
    Lei Li
    Ruiying Zhang
    Lihong V. Wang
    Nature Communications, 9
  • [9] Single-Breath-Hold Multiple-Slice DENSE MRI
    Sigfridsson, Andreas
    Haraldsson, Henrik
    Ebbers, Tino
    Knutsson, Hans
    Sakuma, Hajime
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1411 - 1414
  • [10] Compressed Sensing Single-Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass
    Vincenti, Gabriella
    Monney, Pierre
    Chaptinel, Jerome
    Rutz, Tobias
    Coppo, Simone
    Zenge, Michael O.
    Schmidt, Michaela
    Nadar, Mariappan S.
    Piccini, Davide
    Chevre, Pascal
    Stuber, Matthias
    Schwitter, Juerg
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (09) : 882 - 892