STEREOSELECTIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY WITH FLUOROMETRIC DETECTION FOR THE ISOMERS OF MIVACURIUM IN HUMAN PLASMA

被引:16
|
作者
BROWN, AR [1 ]
JAMES, CD [1 ]
WELCH, RM [1 ]
HARRELSON, JC [1 ]
机构
[1] BURROUGHS WELLCOME CO,DIV PHARMACOKINET & DRUG METAB,3030 CORNWALLIS RD,RES TRIANGLE PK,NC 27709
来源
关键词
D O I
10.1016/0378-4347(92)80430-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic assay with fluorometric detection was developed for the analysis of the stereoisomers of mivacurium, a new short-acting neuromuscular blocker, in plasma. The isomers were isolated form plasma by solid-phase extraction with C18 and anion-exchange cartridges. The extracts were chromatographed on a LiChrosphere 60 RP Select B column (125 mm x 4.6 mm I.D.) using a mobile phase of acetonitrile-water (4:6, v/v) containing 0.005 M octanesulfonic acid. The fluorescence excitation and emission wavelengths were 202 and 320 nm, respectively. The accuracy and precision of the assay, expressed as the percentage deviation of measured values from true values and the percentage coefficient of variation, respectively, were less-than-or-equal-to 10% at all concentrations except for the percentage coefficient of variation at the lower limit of quantitation (5 ng/ml). The assay has been successfully used for the analysis of plasma samples from a pharmacokinetic study in human volunteers.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAYS WITH FLUOROMETRIC DETECTION FOR MIVACURIUM ISOMERS AND THEIR METABOLITES IN HUMAN
    LACROIX, M
    TU, TM
    DONATI, F
    VARIN, F
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02): : 297 - 307
  • [2] Stereoselective high-performance liquid chromatographic assay with fluorometric detection of the three isomers of mivacurium and their cis- and trans-alcohol and ester metabolites in human plasma
    Biederbick, W
    Aydinciouglou, G
    Diefenbach, C
    Theisohn, M
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 685 (02): : 315 - 322
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF CLAVULANATE IN HUMAN-PLASMA AND URINE BY FLUOROMETRIC DETECTION
    HAGINAKA, J
    YASUDA, H
    UNO, T
    NAKAGAWA, T
    JOURNAL OF CHROMATOGRAPHY, 1986, 377 : 269 - 277
  • [4] FLUOROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ASSAY OF FLECAINIDE IN HUMAN-PLASMA
    PLOMP, TA
    MAES, RAA
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1987, 25 (09): : 623 - 624
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR TRIMETREXATE IN HUMAN PLASMA
    BULLEN, WW
    CHANG, T
    WHITFIELD, LR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 526 (01): : 266 - 272
  • [6] A FLUOROMETRIC, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR TRANSGLUTAMINASE ACTIVITY
    FINK, ML
    SHAO, YY
    KERSH, GJ
    ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) : 270 - 276
  • [7] IMPROVED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THE STEREOSELECTIVE DETERMINATION OF MEXILETINE IN PLASMA
    ABOLFATHI, Z
    BELANGER, PM
    GILBERT, M
    ROULEAU, JR
    TURGEON, J
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (02): : 366 - 370
  • [8] STEREOSELECTIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR PIRMENOL ENANTIOMERS IN DOG PLASMA
    JANICZEK, N
    BOCKBRADER, HN
    CHANG, T
    AMIDON, GL
    SMITH, DE
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 571 (1-2): : 179 - 187
  • [9] STEREOSELECTIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FLURBIPROFEN IN HUMAN PLASMA
    GEISSLINGER, G
    MENZELSOGLOWEK, S
    SCHUSTER, O
    BRUNE, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 163 - 167
  • [10] STEREOSELECTIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR BUPIVACAINE ENANTIOMERS
    LEE, EJD
    ANG, SB
    LEE, TL
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 420 (01): : 203 - 206