COULOMETRIC FLOW ANALYZER FOR USE WITH IMMOBILIZED ENZYME REACTORS

被引:49
|
作者
ADAMS, RE [1 ]
CARR, PW [1 ]
机构
[1] UNIV GEORGIA, DEPT CHEM, ATHENS, GA 30602 USA
关键词
D O I
10.1021/ac50029a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow coulometric immobilized enzyme analyzer based on the use of a fast totally electrochemical pH-stat was developed. The insolubilized urease had a Km of 43 mM and an activity of 1000-1200 units/g of glass at its pH optimum of 6.8 in 0.2 M sodium perchlorate. In the absence of phosphate buffer, urea adsorbed on the immobilized enzyme, causing broad peaks. Peak width was decreased by adding 1,3-diaminopropane to the electrolyte. It serves as a competitive inhibitor (Ki = 79 .mu.M) and blocks adsorption of urea. Urea could be analyzed with good precision (3%) in simulated sera and in quality control reference sera. Recoveries of urea added to quality control sera were 100%. The major problem involved in determining urea in human serum was a high and irreproducible blank which limited the precision to about 5%.
引用
收藏
页码:944 / 950
页数:7
相关论文
共 50 条
  • [1] USE OF IMMOBILIZED ENZYME REACTORS IN FLOW-INJECTION ANALYSIS
    HO, MH
    METHODS IN ENZYMOLOGY, 1988, 137 : 271 - 287
  • [2] FLOW DYNAMICS OF IMMOBILIZED ENZYME REACTORS
    CHING, CB
    HO, YY
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1984, 20 (05) : 303 - 309
  • [3] MULTILAYER IMMOBILIZED ENZYME FLOW REACTORS
    GOLDSTEIN, L
    SHEMER, L
    GRANOT, R
    FREEMAN, A
    SOKOLOVSKY, M
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1979, 15 (01): : 96 - 97
  • [4] MEMBRANE-TYPE IMMOBILIZED ENZYME REACTORS FOR USE IN FLOW-INJECTION ANALYSIS
    CLIFFE, S
    FILIPPINI, C
    SCHNEIDER, M
    FAWER, M
    ANALYTICA CHIMICA ACTA, 1992, 256 (01) : 53 - 57
  • [5] IMMOBILIZED ENZYME REACTORS
    ONEILL, SP
    REVIEWS OF PURE AND APPLIED CHEMISTRY, 1972, 22 (DEC): : 133 - 143
  • [6] USE OF IMMOBILIZED ENZYME REACTORS IN AUTOMATED CLINICAL ANALYSES
    MURACHI, T
    ENZYME ENGINEERING, 1982, 6 : 369 - 375
  • [7] USE OF IMMOBILIZED ENZYME COLUMN REACTORS IN CLINICAL ANALYSIS
    MURACHI, T
    TABATA, M
    METHODS IN ENZYMOLOGY, 1988, 137 : 260 - 271
  • [8] COMPARISON OF IMMOBILIZED ENZYME REACTORS FOR FLOW-INJECTION SYSTEMS
    THOMPSON, RQ
    KIM, H
    MILLER, CE
    ANALYTICA CHIMICA ACTA, 1987, 198 : 165 - 172
  • [9] KINETICS IN IMMOBILIZED ENZYME REACTORS
    BUCHHOLZ, K
    BIOTECHNOLOGY LETTERS, 1982, 4 (01) : 70 - 70
  • [10] Immobilized enzyme reactors in proteomics
    Ma, Junfeng
    Zhang, Lihua
    Liang, Zhen
    Shan, Yichu
    Zhang, Yukui
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (05) : 691 - 702