X-SAR RADIOMETRIC CALIBRATION AND DATA QUALITY

被引:35
|
作者
ZINK, M
BAMLER, R
机构
[1] DLR, German Aerospace Research Establishment
来源
关键词
Synthetic aperture radar;
D O I
10.1109/36.406670
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
In April and October, 1994 the X-SAR was flown as part of the SIR-C/X-SAR space radar laboratory missions (SRL-1/2) on the Space Shuttle. Amongst other activities DLR is responsible for the calibration of all X-SAR data products and is running the German Processing and Archiving Facility (D-PAF). Calibration activities included three major parts. Before the first mission, we performed a detailed analysis of the overall system to localize the main error sources and developed algorithms and procedures to correct these errors, During the missions we concentrated our efforts on calibration campaigns at the Oberpfaffenhofen super test site. Post mission activities included the determination of the antenna pattern and the absolute calibration factor as well as detailed performance analyses. This paper describes the overall approach to radiometrically calibrate the X-SAR and provides information on system performance and data quality to users in the different application fields.
引用
收藏
页码:840 / 847
页数:8
相关论文
共 50 条
  • [1] SRTM X-SAR calibration results
    Eineder, M
    Breit, H
    Adam, N
    Holzner, J
    Suchandt, S
    Rabus, B
    IGARSS 2001: SCANNING THE PRESENT AND RESOLVING THE FUTURE, VOLS 1-7, PROCEEDINGS, 2001, : 748 - 750
  • [2] Calibration of the X-SAR system on SRTM
    Zink, M
    Geudtner, D
    CEOS SAR WORKSHOP, 2000, 450 : 375 - 377
  • [4] CALIBRATION AND PERFORMANCE ANALYSIS OF THE X-SAR SYSTEM
    SEIFERT, FM
    ZINK, M
    KIETZMANN, H
    BLOTSCHER, H
    CALIBRATION AND APPLICATIONS OF SATELLITE SENSORS FOR ENVIRONMENTAL MONITORING, 1995, 17 (01): : 71 - 74
  • [5] The Airborne X-SAR Calibration with High Resolution
    Shen, Ting
    Li, Jun
    Wang, Zhirui
    Huang, Lei
    2016 CIE INTERNATIONAL CONFERENCE ON RADAR (RADAR), 2016,
  • [6] X-SAR/SRTM instrument phase error calibration
    Werner, M
    Haeusler, M
    IGARSS 2001: SCANNING THE PRESENT AND RESOLVING THE FUTURE, VOLS 1-7, PROCEEDINGS, 2001, : 742 - 744
  • [7] Filtering of interferometric SRTM X-SAR data
    Eineder, M
    Rabus, B
    Holzner, J
    Suchandt, S
    Knöpfle, W
    IGARSS 2002: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM AND 24TH CANADIAN SYMPOSIUM ON REMOTE SENSING, VOLS I-VI, PROCEEDINGS: REMOTE SENSING: INTEGRATING OUR VIEW OF THE PLANET, 2002, : 164 - 166
  • [8] Calibration of the shuttle radar topography mission X-SAR instrument using a synthetic altimetry data model
    Helm, A
    Braun, A
    Eickschen, S
    Schöne, T
    CANADIAN JOURNAL OF REMOTE SENSING, 2002, 28 (04) : 573 - 580
  • [9] X-SAR INTERFEROMETRY - FIRST RESULTS
    MOREIRA, J
    SCHWABISCH, M
    FORNARO, G
    LANARI, R
    BAMLER, R
    JUST, D
    STEINBRECHER, U
    BREIT, H
    EINEDER, M
    FRANCESCHETTI, G
    GEUDTNER, D
    RINKEL, H
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1995, 33 (04): : 950 - 956
  • [10] Analysis of ground moving objects using SRTM/X-SAR data
    Suchandt, Steffen
    Eineder, Michael
    Breit, Helko
    Runge, Hartmut
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2006, 61 (3-4) : 209 - 224