RADIAL BUILD BETWEEN HELICAL-COIL AND PLASMA IN THE LARGE HELICAL DEVICE

被引:3
|
作者
OHYABU, N
YAMAZAKI, K
HANTAO, JI
IMAGAWA, S
KANEKO, H
MORIMOTO, S
NODA, N
SATOW, T
YAMAMOTO, J
MOTOJIMA, O
机构
[1] National Institute for Fusion Science, Chikusa-ku, Nagoya
关键词
D O I
10.1016/0920-3796(93)90026-E
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Large Helical Device (LHD) is a heliotron/torsatron-type confinement device (B = 4 T, R = 3.9 m) equipped with a helical divertor. In the LHD configuration, the plasma region is shifted inwards approximately a third of the plasma minor radius relative to the center of the two pairing helical coils, thus making the distance between the coil center and the edge plasma small, 328 mm on the small major radius side of the torus. Within this space, many components must be installed, such as the superconducting helical coil (163), its coil can (45), the thermal shield (30), the vacuum gap (35), the plasma vacuum vessel (15), the first wall (25) (the numbers in the parentheses are allocated radial space in mm for the respective components). Effective edge plasma control by the divertor requires a space of more than 15 mm between the plasma and the first wall. To meet the above space requirement. the thickness of the helical coil is designed to be as small as possible, yet the coil current density and maximum field strength are within the limits of reliable coil operation.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 50 条
  • [1] DESIGN AND FABRICATION OF POOL COOLED HELICAL-COIL AS AN RESEARCH-AND-DEVELOPMENT PROGRAM FOR LARGE HELICAL DEVICE
    YANAGI, N
    TAKAHATA, K
    MITO, T
    YAMAMOTO, J
    MOTOJIMA, O
    SAITO, R
    SUZUKI, S
    IIDA, F
    OGATA, H
    IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) : 2357 - 2360
  • [2] THE HELICAL COORDINATE SYSTEM AND THE TEMPERATURE DISTRIBUTION INSIDE A HELICAL-COIL
    WANG, CY
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1980, 47 (04): : 951 - 953
  • [3] SUPERCONDUCTING JOINT OF THE DEMOUNTABLE HELICAL-COIL
    HORIUCHI, T
    MATSUMOTO, K
    HAMADA, M
    UO, K
    MOTOJIMA, O
    NAKASUGA, M
    FUSION TECHNOLOGY, 1985, 8 (01): : 1654 - 1658
  • [4] OPTIMIZATION OF HELICAL-COIL APPLICATORS FOR HYPERTHERMIA
    HAGMANN, MJ
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1988, 36 (01) : 148 - 150
  • [5] HELICAL HELIAC COIL RECONSTRUCTION BY HIGHER HARMONIC MODULATION ON L=1 HELICAL-COIL
    KOGOSHI, S
    ABE, T
    FUJIKAWA, G
    KATSURAI, M
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1992, 61 (12) : 4267 - 4270
  • [6] COUPLING EFFICIENCY OF HELICAL-COIL HYPERTHERMIA APPLICATIONS
    HAGMANN, MJ
    LEVIN, RL
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (07) : 539 - 540
  • [7] HELICAL-COIL MEASUREMENTS ON ZT-40
    MILLER, G
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (08): : 1026 - 1026
  • [8] NUMERICAL EVALUATION OF THE HELICAL-COIL APPLICATOR FOR HYPERTHERMIA
    HAGMANN, MJ
    LEVIN, RL
    RADIATION RESEARCH, 1983, 94 (03) : 534 - 534
  • [9] STRESS-ANALYSIS OF HELICAL-COIL SPRINGS
    SHIMOSEKI, M
    HAYASAKA, Y
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1983, 26 (217): : 1226 - 1229
  • [10] DESIGNING A HELICAL-COIL HEAT-EXCHANGER
    PATIL, RK
    SHENDE, BW
    GHOSH, PK