A COMPARISON OF 3 DESK-TOP CHEMISTRY ANALYZERS FOR THE PEDIATRIC PRACTICE

被引:4
|
作者
HICKS, JM
IOSEFSOHN, M
GREENBERG, L
机构
[1] GEORGE WASHINGTON UNIV,DEPT CHILD HLTH & DEV,WASHINGTON,DC
[2] GEORGE WASHINGTON UNIV,DEPT PATHOL,WASHINGTON,DC
关键词
D O I
10.1177/000992289103000403
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Three desktop chemistry analyzers most frequently utilized in physicians' offices are compared for performance and precision: the DT60 (Kodak), Vision(TM) (Abbott), and Reflotron(R) (Boehringer-Mannheim). The manufacturers' instructions were followed for all the reagents, calibrators and controls provided with each analyzer used. Precision, stability, dynamic range, interferences, and comparison of analyses of 50-100 patient samples with standard laboratory instruments were evaluated. Within-run precision on all three instruments was acceptable, the coefficient of variation (% CV) ranging from 0.8-5.4% and run-to-run precision CV of 1.1-7.3%. Within-run precision for glucose, blood urea, nitrogen, cholesterol and sodium for an experienced technologist, a clerk without any laboratory experience and a physician with no recent laboratory training were compared: the total CV varied between 1.1 and 6.3%. There are differences in the way bilirubin and hemoglobin interfere with the chemistries on the analyzers. Instrument size, available analyses, reagent cost and ease of operation were also assessed. The data suggest that all three analyzers performed well and would be suitable for the pediatric office setting.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 50 条
  • [1] DESK-TOP ANALYZERS
    PATERSON, A
    NEW SCIENTIST, 1989, 121 (1657) : 69 - 69
  • [2] THE USE OF DESK-TOP CHOLESTEROL ANALYZERS IN GENERAL-PRACTICE
    SUMMERTON, A
    SUMMERTON, N
    PUBLIC HEALTH, 1995, 109 (05) : 363 - 367
  • [3] WHEN IS A DESK-TOP NOT A DESK-TOP
    BRAIN, M
    BYTE, 1989, 14 (07): : 36 - 36
  • [4] COMPARISON OF THE USE OF 4 DESK-TOP ANALYZERS IN 6 URBAN GENERAL PRACTICES
    HOBBS, FDR
    BROUGHTON, PMG
    KENKRE, JE
    THORPE, GHG
    BATKI, A
    BRITISH JOURNAL OF GENERAL PRACTICE, 1992, 42 (361): : 317 - 321
  • [5] INTERFERENCE BY CEPHALOSPORINS WITH CREATININE MEASUREMENT BY DESK-TOP ANALYZERS
    NANJI, AA
    POON, R
    HINBERG, I
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1987, 33 (04) : 427 - 429
  • [6] DESK-TOP PROCESSOR-BASED INTERFACE FOR CHEMICAL ANALYZERS
    DYDULA, JI
    LAURITSEN, OS
    NIELSEN, TH
    JOURNAL OF AUTOMATIC CHEMISTRY, 1982, 4 (02): : 104 - 104
  • [7] DESK-TOP PUBLISHING - ANOTHER VICTORY FOR THE DESK-TOP
    DRESSLER, FRS
    SEYBOLD OUTLOOK ON PROFESSIONAL COMPUTING, 1986, 4 (11): : 9 - 12
  • [8] Desk-top
    Bidgood, Ruth
    POETRY WALES, 2012, 48 (02): : 12 - 12
  • [9] DESK-TOP PUBLISHING AND DESK-TOP COMMUNICATIONS - A MATCHED SET
    不详
    SEYBOLD OUTLOOK ON PROFESSIONAL COMPUTING, 1987, 5 (06): : 11 - 11
  • [10] DESK-TOP ANALYZERS - QUALITY OF RESULTS OBTAINED BY MEDICAL OFFICE PERSONNEL
    NANJI, AA
    POON, R
    HINBERG, I
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1988, 138 (06) : 517 - 520