EFFICIENCY CALIBRATION OF A GE(LI) DETECTOR BY ABSOLUTE COUNTING OF FALLOUT NUCLIDES BY MEANS OF 4PI BETA-GAMMA COINCIDENCE METHOD

被引:1
|
作者
WEINREICH, R [1 ]
机构
[1] UNIV MAINZ,INST KERN CHEM,MAINZ,FED REP GER
来源
NUCLEAR INSTRUMENTS & METHODS | 1975年 / 125卷 / 04期
关键词
D O I
10.1016/0029-554X(75)90478-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:601 / 603
页数:3
相关论文
共 24 条
  • [1] ABSOLUTE MEASUREMENTS OF RADIOACTIVITY USING 4PI BETA-GAMMA COINCIDENCE METHOD
    WOOD, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 133 - &
  • [2] Absolute Efficiency Calibration of a Beta-Gamma Detector
    Cooper, Matthew W.
    Ely, James H.
    Haas, Derek A.
    Hayes, James C.
    McIntyre, Justin I.
    Lidey, Lance S.
    Schrom, Brian T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 676 - 680
  • [3] Improvement of accuracy of efficiency extrapolation method in 4 pi beta-gamma coincidence counting
    Yan, CG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 383 - 387
  • [4] 4PI-BETA-GAMMA COINCIDENCE COUNTING FOR CALIBRATION OF NUCLIDES WITH COMPLEX DECAY SCHEMES
    HOUTERMANS, H
    MIGUEL, M
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1962, 13 (MAR): : 137 - &
  • [5] PROCESSING OF EXPERIMENTAL-DATA OBTAINED AT ABSOLUTE STANDARDIZATION OF RADIOACTIVE SOURCES AND SOLUTIONS BY 4PI BETA-GAMMA COINCIDENCE METHOD
    SAHAGIA, M
    DUMITRESCU, R
    DEBERTH, C
    REVUE ROUMAINE DE PHYSIQUE, 1976, 21 (07): : 745 - 754
  • [6] ABSOLUTE BETA-STANDARDIZATION USING 4-PI BETA-GAMMA COINCIDENCE TECHNIQUES
    GUNNINK, R
    COLBY, LJ
    COBBLE, JW
    ANALYTICAL CHEMISTRY, 1959, 31 (05) : 796 - 798
  • [7] A new conducting polymer radioactive source support for 4 pi beta-gamma coincidence counting
    deSanoit, J
    Geffroy, B
    Rosilio, C
    Hainos, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 131 (1-4): : 305 - 312
  • [8] Radioxenon beta-gamma coincidence efficiency for a SAUNA detector by Geant4 simulation
    Zahran, I
    Ababneh, E.
    Okoor, S.
    Albqoor, A.
    PHYSICA SCRIPTA, 2024, 99 (10)
  • [9] STANDARDIZATION OF I-129 BY THE TDCR LIQUID SCINTILLATION METHOD AND 4-PI BETA-GAMMA COINCIDENCE COUNTING
    CASSETTE, P
    BOUCHARD, J
    CHAUVENET, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 339 - 342
  • [10] 4PI BETA-GAMMA-COINCIDENCE SPECTROMETER USING SI(LI) AND NAI(TL) DETECTORS
    GILS, HJ
    WIESNER, W
    LOHKEN, R
    FLOTHMAN.D
    NUCLEAR INSTRUMENTS & METHODS, 1972, 105 (02): : 179 - &