STATIC AND DYNAMIC STRESSES DURING VALVE CLOSURE OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS

被引:2
|
作者
CHIANG, TH [1 ]
LAM, H [1 ]
QUIJANO, R [1 ]
DONHAM, R [1 ]
GILLIAM, P [1 ]
HEINZ, LA [1 ]
机构
[1] PDA ENGN INC,COSTA MESA,CA
来源
关键词
BILEAFLET MECHANICAL HEART VALVE; STATIC STRESSES; DYNAMIC STRESSES; FINITE ELEMENT ANALYSIS; CONTACT AND COMPLIANCE;
D O I
10.1177/039139889101401207
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of contact geometry and component compliance on the magnitude, distribution, and state of various types of stresses on a bileaflet mechanical heart valve prosthesis during valve closure was analyzed using an Edwards-Duromedics(TM) mitral valve as example. Static and dynamic stresses developing on both the leaflet and pivot ball during valve closure were modeled using finite element analysis (FEA). Uniform contact between the leaflet and housing as well as between the pivot ball and pivot slot can significantly reduce both static and dynamic stresses around the contact area. The level of the dynamic flexural stresses can be an order of magnitude higher than that of the static stresses. When both the radial and axial compliance of the housing are taken into consideration, peak dynamic stress was more than 40% less than that generated through the impact between a moving leaflet and a non-compliant rigid housing.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 50 条
  • [1] A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS
    BLUESTEIN, D
    EINAV, S
    HWANG, NHC
    JOURNAL OF BIOMECHANICS, 1994, 27 (11) : 1369 - 1378
  • [2] A STUDY OF THE STABILITY OF ORIENTATION IN THE CARBOMEDICS BILEAFLET HEART-VALVE PROSTHESIS
    CHAMBERS, JB
    DEVERALL, PB
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (08) : 442 - 445
  • [3] 2 YEARS EXPERIENCE WITH THE DUROMEDICS BILEAFLET HEART-VALVE PROSTHESIS
    MORITZ, A
    KLEPETKO, W
    GRABENWOGER, F
    SCHREINER, W
    KLICPERA, M
    KRONIK, G
    WOLNER, E
    TEXAS HEART INSTITUTE JOURNAL, 1985, 12 (04) : 315 - 322
  • [4] Near Valve Flows and Potential Blood Damage During Closure of a Bileaflet Mechanical Heart Valve
    Herbertson, L. H.
    Deutsch, S.
    Manning, K. B.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (09):
  • [5] HEART-VALVE REPLACEMENT WITH THE DUROMEDICS BILEAFLET VALVE IN 400 PATIENTS
    KLEPETKO, W
    MORITZ, A
    SCHLICK, W
    KRONIK, G
    JUNG, M
    SCHREINER, W
    WOLNER, E
    CIRCULATION, 1986, 74 (04) : 340 - 340
  • [6] CFD simulation of a novel bileaflet mechanical heart valve prosthesis
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 868 - 868
  • [7] Durability testing of a polymeric bileaflet mechanical heart valve prosthesis
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 867 - 867
  • [8] WEAR OF HEART-VALVE PROSTHESIS
    HASHIMOTO, S
    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1990, 35 (12) : 858 - 861
  • [9] CHITRA HEART-VALVE PROSTHESIS
    BHUVANESHWAR, GS
    VALIATHAN, MS
    RAMANI, AV
    LAL, GAV
    KUMAR, RS
    ARTIFICIAL ORGANS, 1987, 11 (04) : 326 - 326
  • [10] SELECTION OF HEART-VALVE PROSTHESIS
    BORST, HG
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 34 - 34