SENSITIVITY OF COLUMN AGGLUTINATION TECHNOLOGY IN DETECTING UNEXPECTED RED-CELL ANTIBODIES

被引:12
|
作者
PINKERTON, PH [1 ]
CHAN, R [1 ]
WARD, J [1 ]
COOVADIA, AS [1 ]
机构
[1] UNIV TORONTO,DEPT PATHOL,TORONTO,ON,CANADA
关键词
ANTIGLOBULIN TEST; ANTIBODY SCREENING; COLUMN TECHNIQUE; SENSITIVITY;
D O I
10.1111/j.1365-3148.1993.tb00061.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was conducted to compare a new microtube column agglutination technology (CAT) with a previously described tube saline-indirect antiglobulin test (SIAT) with carefully defined performance in the detection of unexpected antibodies. On testing 117 sera from fresh and frozen stock containing antibodies detectable by SIAT, CAT failed to detect two examples of weak anti-K. All other discrepancies between the two techniques involved antibodies generally regarded as clinically insignificant. Titration studies with anti-D (concentration approximately 10 ng/ml) and 23 other antibodies, and studies with 10 weak antibodies of various blood group systems, showed the two techniques to be of similar sensitivity. Equivocal CAT results requiring repeated testing were found in 4.1% of specimens tested. We conclude that the CAT method adequately meets our requirements in sensitivity of detection of unexpected antibodies in pre-transfusion testing and offers opportunities for savings in technical staff time.
引用
收藏
页码:275 / 279
页数:5
相关论文
共 50 条
  • [1] RED-CELL ABD/RH/K TYPING BY COLUMN AGGLUTINATION TECHNOLOGY
    REIS, KJ
    CUPIDO, A
    JAKWAY, J
    CHACHOWSKI, R
    PUZIO, E
    DAVIES, D
    SETCAVAGE, TM
    TRANSFUSION, 1992, 32 (08) : S16 - S16
  • [2] MECHANISM OF RED-CELL AGGLUTINATION BY IGG ANTIBODIES
    ROMANO, EL
    MOLLISON, PL
    VOX SANGUINIS, 1973, 25 (01) : 28 - 31
  • [3] RED-CELL ANTIBODY SCREENING, RED-CELL ANTIBODY IDENTIFICATION AND COMPATIBILITY TESTING WITH THE COLUMN AGGLUTINATION TECHNOLOGY (CAT) - THE BIOVUE SYSTEM
    LAMY, B
    TISSOT, C
    HEYD, C
    LAMY, C
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 1994, 1 (02) : 121 - 127
  • [4] COLUMN AGGLUTINATION TECHNOLOGY FOR UNEXPECTED ANTIBODY DETECTION
    COOVADIA, AS
    PINKERTON, PH
    WARD, J
    CHAN, R
    TRANSFUSION, 1993, 33 (09) : S19 - S19
  • [5] High-sensitivity detection of clinically significant red blood cell antibodies by the column agglutination technique
    Charong, Nurdina
    Kooltheat, Nateelak
    Plyduang, Thunyaluk
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 30 (11): : 1205 - 1214
  • [6] RED-CELL AGGLUTINATION CAUSED BY VANCOMYCIN
    DOMEN, RE
    GILBERT, DM
    TRANSFUSION, 1987, 27 (06) : 514 - 514
  • [7] AUTOLOGOUS RED-CELL AGGLUTINATION-TEST FOR ANTIBODIES TO FELINE IMMUNODEFICIENCY VIRUS
    WILSON, KM
    ROBINSON, WF
    MITCHELHILL, KI
    BUNDESEN, PG
    KEMP, BE
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 1994, 42 (3-4) : 253 - 263
  • [8] RED-CELL ANTIBODIES
    PALMER, A
    BRITISH MEDICAL JOURNAL, 1987, 294 (6587): : 1568 - 1569
  • [9] RED-CELL ANTIBODIES
    BIRCH, ADJ
    BRITISH MEDICAL JOURNAL, 1987, 295 (6595): : 442 - 442
  • [10] KINETICS OF THE AUTOLOGOUS RED-CELL AGGLUTINATION-TEST
    CATIMEL, B
    WILSON, KM
    KEMP, BE
    JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 165 (02) : 183 - 192