RAPID DIAGNOSIS OF SCHISTOSOMIASIS BY ANTIGEN-DETECTION IN URINE WITH A REAGENT STRIP

被引:51
|
作者
VANETTEN, L
FOLMAN, CC
EGGELTE, TA
KREMSNER, PG
DEELDER, AM
机构
[1] UNIV AMSTERDAM,ACAD MED CTR,DEPT CLIN PHARMACOL,1105 AZ AMSTERDAM,NETHERLANDS
[2] LANDESINST TROP MED BERLIN,D-10179 BERLIN,GERMANY
关键词
D O I
10.1128/JCM.32.10.2404-2406.1994
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
For the rapid and simple diagnosis of schistosomiasis, a reagent strip assay for detection of circulating cathodic antigen (CCA) in urine was developed. The test was based on a previously developed sandwich enzyme-linked immunosorbent assay (ELISA) using a combination of two anti-CCA monoclonal antibodies. For the reagent strip assay, as the capture matrix, monoclonal antibody was coated onto a nitrocellulose membrane and mounted on polyvinyl chloride strips. Urine samples were then tested in an assay consisting of a combined incubation step of the urine sample and biotinylated detecting antibody followed by incubation in streptavidin peroxidase and a subsequent staining. The specificity and the sensitivity of the assay, as determined with urine samples of 61 uninfected controls and 67 Schistosoma mansoni-infected individuals, were 96.7 and 95.5%, respectively. The results of the reagent strip assay compared very well with microscopical parasitological diagnosis by the standard Kato-Katz method for the same individuals. The reagent strip test has a lower detection limit of 1 ng of CCA per ml and can be completed in 75 min. By the inclusion of two reference bands on the strips, standardized reading could be achieved. This reagent strip assay is a promising tool for qualitative diagnosis of S. mansoni infections in control programs.
引用
收藏
页码:2404 / 2406
页数:3
相关论文
共 50 条
  • [1] Diagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen
    van Dam, GJ
    Wichers, JH
    Ferreira, TMF
    Ghati, D
    van Amerongen, A
    Deelder, AM
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (12) : 5458 - 5461
  • [2] RAPID DIAGNOSIS OF STREPTOCOCCUS-PNEUMONIAE INFECTIONS BY ANTIGEN-DETECTION IN URINE, SERUM AND CSF
    VANDERAUWERA, P
    ANDRE, A
    BULLIARD, G
    LEGRAND, JC
    GORDTS, B
    VANLANDUYT, H
    ANNALES DE BIOLOGIE CLINIQUE, 1985, 43 (04) : 401 - 405
  • [3] RAPID DIAGNOSIS OF TYPHOID-FEVER BY ANTIGEN-DETECTION
    SIVADASAN, K
    KURIEN, B
    JOHN, TJ
    LANCET, 1984, 1 (8369): : 134 - 135
  • [5] IMMUNOLOGICAL DIAGNOSIS OF INFECTIOUS-DISEASE BY ANTIGEN-DETECTION IN URINE
    GOOCH, WM
    JOURNAL OF MEDICAL TECHNOLOGY, 1985, 2 (12): : 762 - 765
  • [6] COMPARISON OF URINE FILTRATION AND A CHEMICAL REAGENT STRIP IN THE DIAGNOSIS OF URINARY SCHISTOSOMIASIS IN ETHIOPIA
    BIRRIE, H
    MEDHIN, G
    JEMANEH, L
    EAST AFRICAN MEDICAL JOURNAL, 1995, 72 (03) : 180 - 185
  • [7] RAPID DIAGNOSIS OF CHLAMYDIA-TRACHOMATIS IN MALE-PATIENTS BY ANTIGEN-DETECTION IN URINE SAMPLES
    STARY, A
    HELLERVITOUCH, C
    MULLER, I
    DERMATOLOGY, 1992, 185 (01) : 27 - 31
  • [8] ANTIGEN-DETECTION IN OROPHARYNGEAL SECRETIONS FOR RAPID DIAGNOSIS OF PNEUMOCOCCAL PNEUMONIA
    BOERSMA, WG
    HOLLOWAY, Y
    KUTTSCHRUTTER, H
    LOWENBERG, A
    SNIJDER, JAM
    KOETER, GH
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1993, 12 (03) : 217 - 220
  • [9] ANTIGEN-DETECTION FOR THE DIAGNOSIS OF GONORRHEA
    STAMM, WE
    COLE, B
    FENNELL, C
    BONIN, P
    ARMSTRONG, AS
    HERRMANN, JE
    HOLMES, KK
    JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (03) : 399 - 403
  • [10] Rapid diagnosis of schistosomiasis in Yemen using a simple questionnaire and urine reagent strips
    Bassiouny, H. K.
    Hasab, A. A.
    El-Nimr, N. A.
    Al-Shibani, L. A.
    Al-Waleedi, A. A.
    EASTERN MEDITERRANEAN HEALTH JOURNAL, 2014, 20 (04) : 242 - 249