Development and Validation of LC-MS/MS Assay for the Quantification of Progesterone in Rat Plasma and its Application to Pharmacokinetic Studies

被引:11
|
作者
Sasaki, M. [1 ]
Ochiai, H. [1 ]
Takahashi, K. [2 ]
Suzuki, R. [1 ]
Minato, K. [1 ]
Fujikata, A. [1 ]
机构
[1] ASKA Pharmaceut Co Ltd, Pharmacokinet Res Dept, Res Dev Ctr, Kawasaki, Kanagawa 2138522, Japan
[2] ASKA Pharma Med Co Ltd, Kawasaki, Kanagawa, Japan
关键词
LC-MS/MS; intramuscular administration; vaginal administration; ovariectomized rat; pharmacokinetics; steroids;
D O I
10.1055/s-0034-1389967
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of progesterone levels in rat plasma. Progesterone-d(9) was used as an internal standard (IS). Samples were prepared using salting-out assisted liquid/liquid extraction (SALLE), and the extracts were injected directly onto the LC-MS/MS system. The chromatographic separation was achieved on a CAPCELL PAK C18 MGIII column (100 mm x 2.0 mm, i.d. 5 mu m) using methanol and aqueous 0.1 % formic acid solution gradient as the mobile phase with a constant flow rate of 0.45 mL/min. Electrospray ionization in the positive-ion mode was employed. Multiple reaction monitoring of the precursor to product ion pairs, from m/z 315.20 to m/z 109.10 for progesterone and from m/z 324.26 to m/z 113.07 for the IS, was used for quantification. Good linearity was observed over the concentration range of 0.05-20.00 ng/mL with a weighted (1/x2) linear regression. The intra-and inter-day precision (% relative standard deviation [RSD]) across 3 validation days over the entire concentration range was lower than 6.7 %. Accuracy (% nominal) determined at 5 quality control concentrations was between 94.0 and 103.7 %. The validation method was applied in a pharmacokinetic study evaluating progesterone levels after intramuscular or vaginal administration to ovariectomized (OVX) rats. The area under the plasma concentration-time curve (AUC) calculated after intramuscular administration was more than 4 times higher than the AUC measured following vaginal administration of a comparable dose.
引用
收藏
页码:484 / 489
页数:6
相关论文
共 50 条
  • [1] LC-MS/MS assay for the quantification of foretinib in rat plasma and its application to preclinical pharmacokinetic study
    Guo, Nan
    Zhang, Aiying
    Zhuang, Hui
    Zhang, Changzhen
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (08)
  • [2] Development and validation of an LC-MS/MS method for the determination of DPHB in rat plasma and its application in pharmacokinetic studies
    Wen, Qi
    Li, Hai-Long
    Chen, Feng
    Gong, Jing-Wen
    Guan, Wei-Wei
    Fu, Nai-Guang
    Tan, Yin-Feng
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (12)
  • [3] Development and validation of a sensitive LC-MS/MS assay for the quantification of nizatidine in human plasma and urine and its application to pharmacokinetic study
    Shang, De-Wei
    Wang, Zhan-Zhang
    Ni, Xiao-Jia
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 998 : 80 - 87
  • [4] Development and validation of a sensitive LC-MS/MS assay for the quantification of anserine in human plasma and urine and its application to pharmacokinetic study
    Everaert, Inge
    Baron, Giovanna
    Barbaresi, Silvia
    Gilardoni, Ettore
    Coppa, Crescenzo
    Carini, Marina
    Vistoli, Giulio
    Bex, Tine
    Stautemas, Jan
    Blancquaert, Laura
    Derave, Wim
    Aldini, Giancarlo
    Regazzoni, Luca
    AMINO ACIDS, 2019, 51 (01) : 103 - 114
  • [5] Quantification of endostar in rat plasma by LC-MS/MS and its application in a pharmacokinetic study
    Li, Ying Chun
    Liang, Yan
    Tang, Zhi Yuan
    Xiao, Ya Nan
    Hao, Hai Ping
    Wang, Guang Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 505 - 511
  • [6] Development and validation of a LC-MS/MS assay for quantification of cisplatin in rat plasma and urine
    Shaik, Abdul Naveed
    Altomare, Deborah A.
    Lesko, Lawrence J.
    Trame, Mirjam N.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1046 : 243 - 249
  • [7] Development of an LC-MS/MS method for quantification of kadsurenone in rat plasma and its application to a pharmacokinetic study
    Zhang, Nan
    Li, Rui
    Yu, Haiyao
    Shi, Dan
    Dong, Ning
    Zhang, Sixi
    Wang, Helei
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1754 - 1758
  • [8] Development and validation of novel LC-MS/MS method for determination of Lusutrombopag in rat plasma and its application to pharmacokinetic studies
    Singh, N.
    Bansal, P.
    Maithani, M.
    Chauhan, Y.
    ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (02) : 4162 - 4169
  • [9] Development and validation of an LC-MS/MS method for simultaneous quantification of hesperidin and hesperetin in rat plasma for pharmacokinetic studies
    Lee, Jr-Ting
    Pao, Li-Heng
    Hsieh, Chang-Da
    Huang, Pei-Wei
    Hu, Oliver Yoa-Pu
    ANALYTICAL METHODS, 2017, 9 (22) : 3329 - 3337
  • [10] A simple and sensitive LC-MS/MS method for quantification of Bepridil in rat plasma and its application to pharmacokinetic studies
    Patel, Bhavesh D.
    Palakundam, Nageswararao
    Alamanda, Rajesh
    Gadekar, Ajit R.
    Raje, Amol A.
    Ameta, Rakshit
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 172 : 113 - 119