OPERATIONAL EXPERIENCE WITH VORTEX SOLIDS SEPARATORS FOR COMBINED SEWER OVERFLOW (CSO) CONTROL

被引:8
|
作者
PISANO, WC [1 ]
BROMBACH, H [1 ]
机构
[1] UMWELT & FLUID TECH,BAD MERGENTHEIM,GERMANY
关键词
VORTEX SEPARATOR; LIQUID; SOLIDS-SEPARATION COMBINED SEWER OVERFLOW; QUALITY EFFICIENCY;
D O I
10.2166/wst.1994.0686
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The first vortex solids separator facility in Germany for CSO control was installed in 1987. Solids separation efficiency was optimized in the hydraulic laboratory using scaled down models and artificial tracers to simulate typical sewage particulates. The facility comprises two parallel operating vortex separators servicing an impervious area of 11 ha with a population of 1,500 people. The specific storage of the facility including the separator volume and in-line pipe storage is 7.2 m3/ha, about 1/4 - 1/2 of that required per German standards. A multi-year evaluation program was conducted. The first phase noted operational reliability, hydraulic loads and overflow frequencies. In the second phase pollutant removal efficiencies were monitored. The results were favourable indicating that the separator is now ready for use.
引用
收藏
页码:383 / 391
页数:9
相关论文
共 50 条
  • [1] EXPERIENCE WITH VORTEX SEPARATORS FOR COMBINED SEWER OVERFLOW CONTROL
    BROMBACH, H
    XANTHOPOULOS, C
    HAHN, HH
    PISANO, WC
    WATER SCIENCE AND TECHNOLOGY, 1993, 27 (5-6) : 93 - 104
  • [2] Relationships between rainfall and Combined Sewer Overflow (CSO) occurrences
    Mailhot, A.
    Talbot, G.
    Lavallee, B.
    JOURNAL OF HYDROLOGY, 2015, 523 : 602 - 609
  • [3] DESIGN OF STORMWATER INFILTRATION FOR REDUCTION OF COMBINED SEWER OVERFLOW (CSO)
    PETERSEN, COR
    JACOBSEN, P
    MIKKELSEN, PS
    WATER SCIENCE AND TECHNOLOGY, 1994, 30 (01) : 53 - 61
  • [4] Critical velocity of floatables in Combined Sewer Overflow (CSO) chambers
    Cigana, J
    Lefebvre, G
    Marche, C
    WATER SCIENCE AND TECHNOLOGY, 2001, 44 (2-3) : 287 - 293
  • [6] Evaluation of effectiveness of combined sewer overflow control measures by operational data
    Schroeder, K.
    Riechel, M.
    Matzinger, A.
    Rouault, P.
    Sonnenberg, H.
    Pawlowsky-Reusing, E.
    Gnirss, R.
    WATER SCIENCE AND TECHNOLOGY, 2011, 63 (02) : 325 - 330
  • [7] Determination of COD, BOD, and suspended solids loads during combined sewer overflow (CSO) events in some combined catchments in Spain
    Suárez, J
    Puertas, J
    ECOLOGICAL ENGINEERING, 2005, 24 (03) : 201 - 219
  • [8] Upgrading the North Toronto combined sewer overflow (CSO) storage and treatment facility
    Marsalek, J
    He, C
    Rochfort, Q
    Exall, K
    Wood, J
    Krishnappan, BG
    Seto, P
    Chessie, P
    ENHANCING URBAN ENVIRONMENT BY ENVIRONMENTAL UPGRADING AND RESTORATION, 2004, 43 : 111 - 121
  • [9] CONTROL STRATEGIES FOR COMBINED SEWER OVERFLOW
    HALL, JC
    RISSETTO, CL
    SANTARELLA, JM
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1989, 61 (08): : 1408 - 1413
  • [10] Innovative monitoring of combined sewer overflow (CSO) quality in the Liguori catchnment (Cosenza, Italy)
    Piro, Patrizia
    Carbone, Marco
    Garofalo, Giuseppina
    WATER QUALITY RESEARCH JOURNAL OF CANADA, 2012, 47 (02): : 178 - 185