Side-branch technique for difficult guidewire placement in coronary bifurcation lesion

被引:3
|
作者
He, Xingwei [1 ]
Gao, Bo [1 ]
Liu, Yujian [1 ]
Li, Zhuxi [1 ]
Zeng, Hesong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Div Cardiol, Wuhan, Peoples R China
关键词
Percutaneous coronary intervention; Bifurcation lesion; Side-branch technique;
D O I
10.1016/j.carrev.2015.03.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite tremendous advances in technology and skills, percutaneous coronary intervention (PCI) of bifurcation lesion (BL) remains a particular challenge for the interventionalist. During bifurcation PCI, safe guidewire placement in themain branch (MB) and the side branch (SB) is the first step for successful procedure. However, in certain cases, the complex pattern of vessel anatomy and the mix of plaque distribution may make target vessel wiring highly challenging. Therefore, specific techniques are required for solving this problem. Hereby, we describe a new use of side-branch technique for difficult guidewire placement in BL. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:59 / 62
页数:4
相关论文
共 50 条
  • [1] Successful PCI of RCA CTO Bifurcation Lesion Using Side-Branch Technique
    Liu, Bing
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S225 - S227
  • [2] A TECHNIQUE FOR DIFFICULT-TO-CROSS OSTIAL SIDE-BRANCH LESIONS
    DAWOOD, MM
    SAPERIA, GM
    BENOTTI, JR
    JOURNAL OF INVASIVE CARDIOLOGY, 1995, 7 (07): : 214 - 216
  • [3] Rotastenting of a bifurcation lesion using the Jo Med® S side-branch stent
    Ramsdale, DR
    Chester, MR
    JOURNAL OF INVASIVE CARDIOLOGY, 1998, 10 (04): : 220 - 222
  • [4] Rupture of bioresorbable vascular scaffold after side-branch dilation in bifurcation lesion
    Pan Alvarez-Osorio, M.
    Romero, M.
    Ojeda, S.
    Suarez De Lezo, J., Jr.
    Segura, J.
    Mazuelos, F.
    Lopez, J.
    Martin, P.
    Medina, A.
    Suarez De Lezo, J.
    EUROPEAN HEART JOURNAL, 2014, 35 : 12 - 12
  • [5] OPTIMAL STRATEGY FOR SIDE BRANCH STENTING IN CORONARY BIFURCATION LESION
    Song, Young Bin
    Hahn, Joo-Yong
    Choi, Jin-Ho
    Choi, Seung-Hyuk
    Gwon, Hyeon-Cheol
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E84 - E84
  • [6] Safety of hydrophilic guidewires used for side-branch protection during stenting and proximal optimization technique in coronary bifurcation lesions
    Chatterjee, Arka
    Brott, Brigitta C.
    Foley, Robin
    Alli, Oluseun
    Sasse, Mark
    Ahmed, Mustafa
    Al Solaiman, Firas
    Reddy, Gautam
    Ather, Sameer
    Leesar, Massoud A.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2016, 17 (07) : 456 - 462
  • [7] Accordion Stent Deformation upon Retrieval of a Side-Branch Protective Guidewire
    Cheng, Shih-Tsung
    Su, Cheng-Wen
    Liau, Chiau-Suong
    Ko, Yu-Lin
    ACTA CARDIOLOGICA SINICA, 2015, 31 (06) : 568 - 571
  • [8] Uncovered non-apposed side-branch struts in a bifurcation lesion: a nidus for late stent thrombosis
    Jin, Chongying
    Torii, Ryo
    Ramasamy, Anantharaman
    Kitslaar, Pieter
    Fu, Guosheng
    Baumbach, Andreas
    Bourantas, Christos, V
    HELLENIC JOURNAL OF CARDIOLOGY, 2022, 63 : 96 - 98
  • [9] Fracture of Bioresorbable Vascular Scaffold After Side-Branch Balloon Dilation in Bifurcation Coronary Narrowings
    Pan, Manuel
    Romero, Miguel
    Ojeda, Soledad
    Suarez de Lezo, Javier
    Segura, Jose
    Mazuelos, Francisco
    Martin, Pedro
    Medina, Alfonso
    Suarez de Lezo, Jose
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (07): : 1045 - 1049
  • [10] A practical technique to protect the side branch during PCI for coronary bifurcation lesions: Side branch balloon opening technique
    Chen, Mantian
    Shen, Chenxing
    Zhang, Yachen
    Men, Shu
    Sun, Yinggang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C172 - C173