DETERMINATION OF PROGRAM PROTECTION FACTORS FOR HALF-MASK RESPIRATORS USED AT A MINERAL SANDS SEPARATION PLANT

被引:0
|
作者
HEWSON, GS
RALPH, MI
机构
来源
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A study was conducted at a mineral sands separation plant to evaluate the workplace performance of half-mask filter cartridge respirators. Inhalation exposure was estimated by measuring the dust and radioactivity concentration inside the respirator while it was worn or hanging around the worker's neck. The program protection factor was determined by simultaneously measuring inside-mask and ambient (outside-mask) concentrations. A total of 27 tests were conducted, covering three brands of half-mask respirators;facial hair on test subjects ranged from clean-shaven to bearded. Program protection factors varied from 1.8 to 13 for dust exposure and 2.5 to 21 for radioactivity exposure. The geometric mean program protection factor over all tests was 5.1 (geometric standard deviation [GSD] = 1.7) for dust exposure and 7.5 (GSD = 1.7) for radioactivity exposure. A minimum program protection factor of 3.5 could be applied to ambient airborne concentration data to obtain a conservative, but more realistic, estimate of inhalation exposure on a worker category basis.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 5 条
  • [1] THE ASSIGNED PROTECTION FACTOR OF 10 FOR HALF-MASK RESPIRATORS
    NELSON, TJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1995, 56 (07): : 717 - 724
  • [2] VARIABILITY IN PROTECTION AFFORDED BY HALF-MASK RESPIRATORS AGAINST STYRENE EXPOSURE IN THE FIELD
    GALVIN, K
    SELVIN, S
    SPEAR, RC
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1990, 51 (12): : 625 - 631
  • [3] Total outward leakage of half-mask respirators and surgical masks used for source control
    Myers, Warren R.
    Yang, Weihua
    Ryan, Kenneth J.
    Bergman, Michael S.
    Fisher, Edward M.
    Soo, Jhy-Charm
    Zhuang, Ziqing
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2023, 20 (12) : 610 - 620
  • [4] MEASUREMENT OF PROTECTION FACTORS OF CHEMICAL CARTRIDGE, HALF-MASK RESPIRATORS UNDER WORKING-CONDITIONS IN A COPPER SMELTER
    MOORE, DE
    SMITH, TJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1976, 37 (08): : 453 - 458
  • [5] Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators
    Oestenstad, Riedar Kent
    Bartolucci, Alfred A.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (06) : 332 - 341