MAGNETIC-RESONANCE-IMAGING OF FLOW DYNAMICS IN THE CIRCLE OF WILLIS

被引:86
|
作者
EDELMAN, RR
MATTLE, HP
OREILLY, GV
WENTZ, KU
LIU, C
ZHAO, B
机构
[1] SHANDONG MED IMAGING RES INST,JINAN,PEOPLES R CHINA
[2] NEW ENGLAND DEACONESS HOSP,DEPT RADIOL,BOSTON,MA 02215
[3] UNIV HEIDELBERG,KLINIKUM MANNHEIM,W-6800 MANNHEIM 1,GERMANY
[4] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
Cerebral blood flow; Circle of Willis; Magnetic resonance imaging; Ultrasonics;
D O I
10.1161/01.STR.21.1.56
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Magnetic resonance angiography was applied to the study of blood flow dynamics in the circle of Willis in nine patients with cerebrovascular disease and two normal volunteers. In conjunction with two-dimensional or three-dimensional gradient-echo acquisitions, selective presaturation of individual vessels was used to determine the direction of blood flow and the origin of the vascular supply. Presaturation causes signal loss within the territory supplied by the presaturated artery, without affecting vessels not crossing the presaturation slab. The results were correlated with those from transcranial Doppler sonography and conventional angiography. Magnetic resonance angiography was able to demonstrate the direction of blood flow, the presence or absence of collateral blood flow, and the blood supply to the pericallosal arteries, as well as the presence of a fetal posterior circulation. Magnetic resonance angiography is a noninvasive means for imaging the blood supply of the major intracranial arteries. © 1990 American Heart Association, Inc.
引用
收藏
页码:56 / 65
页数:10
相关论文
共 50 条
  • [1] MAGNETIC-RESONANCE-IMAGING FLOW
    BEST, JJK
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (717): : 944 - 944
  • [2] Circle of Willis collateral flow investigated by magnetic resonance angiography
    Hartkamp, MJ
    van der Grond, J
    van Everdingen, KJ
    Hillen, B
    Mali, WPTM
    STROKE, 1999, 30 (12) : 2671 - 2678
  • [3] MAGNETIC-RESONANCE-IMAGING OF BLOOD-FLOW
    WALUCH, V
    SEMINARS IN NEUROLOGY, 1986, 6 (01) : 65 - 71
  • [4] MEASURING NONCONSTANT FLOW IN MAGNETIC-RESONANCE-IMAGING
    IZEN, SH
    HAACKE, EM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) : 450 - 460
  • [5] DESCRIPTION OF FLOW PHENOMENA IN MAGNETIC-RESONANCE-IMAGING
    DEIMLING, M
    MUELLER, E
    LENZ, G
    BARTH, K
    FRITSCHY, P
    SEIDERER, M
    REINHARDT, ER
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1986, 55 (1-2) : 37 - 51
  • [6] FLOW-ENHANCED MAGNETIC-RESONANCE-IMAGING
    CHENEVERT, TL
    MEDICAL PHYSICS, 1986, 13 (02) : 177 - 181
  • [7] Blood-flow models of the circle of Willis from magnetic resonance data
    Juan R. Cebral
    Marcelo A. Castro
    Orlando Soto
    Rainald Löhner
    Noam Alperin
    Journal of Engineering Mathematics, 2003, 47 : 369 - 386
  • [8] Blood-flow models of the circle of Willis from magnetic resonance data
    Cebral, JR
    Castro, MA
    Soto, O
    Löhner, R
    Alperin, N
    JOURNAL OF ENGINEERING MATHEMATICS, 2003, 47 (3-4) : 369 - 386
  • [9] MAGNETIC-RESONANCE-IMAGING
    TRESS, BM
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1986, 56 (03): : 188 - 189
  • [10] MAGNETIC-RESONANCE-IMAGING
    GINGELL, JC
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1990, 83 (07) : 471 - 473