Predicting mouse vertebra strength with micro-computed tomography-derived finite element analysis

被引:17
|
作者
Nyman, Jeffry S. [1 ,2 ,3 ,4 ]
Uppuganti, Sasidhar [2 ]
Makowski, Alexander J. [1 ,3 ,4 ]
Rowland, Barbara J. [1 ,4 ]
Merkel, Alyssa R. [4 ,5 ]
Sterling, Julie A. [1 ,4 ,5 ,6 ]
Bredbenner, Todd L. [7 ]
Perrien, Daniel S. [1 ,2 ,4 ,8 ]
机构
[1] Tennessee Valley Healthcare Syst, Dept Vet Affairs, Nashville, TN USA
[2] Vanderbilt Univ, Med Ctr East, Dept Orthopaed Surg & Rehabil, South Tower,Suite 4200, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Biomed Engn, Nashville, TN USA
[4] Vanderbilt Univ, Med Ctr, Ctr Bone Biol, Nashville, TN USA
[5] Vanderbilt Univ, Med Ctr, Dept Med, Div Clin Pharmacol, Nashville, TN USA
[6] Vanderbilt Univ, Med Ctr, Dept Canc Biol, Nashville, TN USA
[7] Southwest Res Inst, Musculoskeletal Biomech Sect, San Antonio, TX USA
[8] Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN USA
来源
BONEKEY REPORTS | 2015年 / 4卷
关键词
D O I
10.1038/bonekey.2015.31
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
As in clinical studies, finite element analysis (FEA) developed from computed tomography (CT) images of bones are useful in pre-clinical rodent studies assessing treatment effects on vertebral body (VB) strength. Since strength predictions from microCT-derived FEAs (mu FEA) have not been validated against experimental measurements of mouse VB strength, a parametric analysis exploring material and failure definitions was performed to determine whether elastic mu FEAs with linear failure criteria could reasonably assess VB strength in two studies, treatment and genetic, with differences in bone volume fraction between the control and the experimental groups. VBs were scanned with a 12-mu m voxel size, and voxels were directly converted to 8-node, hexahedral elements. The coefficient of determination or R-2 between predicted VB strength and experimental VB strength, as determined from compression tests, was 62.3% for the treatment study and 85.3% for the genetic study when using a homogenous tissue modulus (E-t) of 18 GPa for all elements, a failure volume of 2%, and an equivalent failure strain of 0.007. The difference between prediction and measurement (that is, error) increased when lowering the failure volume to 0.1% or increasing it to 4%. Using inhomogeneous tissue density-specific moduli improved the R-2 between predicted and experimental strength when compared with uniform E-t = 18 GPa. Also, the optimum failure volume is higher for the inhomogeneous than for the homogeneous material definition. Regardless of model assumptions, mu FEA can assess differences in murine VB strength between experimental groups when the expected difference in strength is at least 20%.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Predicting the permeability of trabecular bone by micro-computed tomography and finite element modeling
    Sandino, Clara
    Kroliczek, Paul
    McErlain, David D.
    Boyd, Steven K.
    JOURNAL OF BIOMECHANICS, 2014, 47 (12) : 3129 - 3134
  • [2] MODELING DENTAL IMPLANTS WITH FINITE ELEMENT ANALYSIS AND MICRO-COMPUTED TOMOGRAPHY
    Tsafnat, Naomi
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 719 - 720
  • [3] Finite element analysis of the mechanical properties of cellular aluminium based on micro-computed tomography
    Veyhl, C.
    Belova, I. V.
    Murch, G. E.
    Fiedler, T.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2011, 528 (13-14): : 4550 - 4555
  • [4] Longitudinal micro-computed tomography-derived biomarkers quantify non-resolving lung fibrosis in a silicosis mouse model
    Dekoster, Kaat
    Decaesteker, Tatjana
    Berghen, Nathalie
    Van den Brouckes, Sofie
    Jonckheere, Anne-Charlotte
    Wouters, Jens
    Krouglov, Anton
    Lories, Rik
    De Langhe, Ellen
    Hoets, Peter
    Verbeken, Erik
    Vanoirbeek, Jeroen
    Velde, Greetje Vande
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] Longitudinal micro-computed tomography-derived biomarkers quantify non-resolving lung fibrosis in a silicosis mouse model
    Kaat Dekoster
    Tatjana Decaesteker
    Nathalie Berghen
    Sofie Van den Broucke
    Anne-Charlotte Jonckheere
    Jens Wouters
    Anton Krouglov
    Rik Lories
    Ellen De Langhe
    Peter Hoet
    Erik Verbeken
    Jeroen Vanoirbeek
    Greetje Vande Velde
    Scientific Reports, 10
  • [6] Analysis of Progressive Damage in Fuze Electronics using Micro-Computed Tomography and Finite Element Models
    Lall, Pradeep
    Kothari, Nakul
    Deep, John
    Lowe, Ryan
    PROCEEDINGS OF THE 17TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2018), 2018, : 1160 - 1168
  • [7] Structure and micro-computed tomography-based finite element modeling of Toucan beak
    Seki, Yasuaki
    Mackey, Mason
    Meyers, Marc A.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 9 : 1 - 8
  • [8] Micro-computed tomography and correlative histology of the mouse lung
    Hayes, BP
    Blyth, D
    Pedrick, M
    Brown, G
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2004, 52 : S61 - S61
  • [9] Micro-computed tomography for analysis of urinary calculi
    Williams, James C., Jr.
    McAteer, James A.
    Evan, Andrew P.
    Lingeman, James E.
    UROLOGICAL RESEARCH, 2010, 38 (06): : 477 - 484
  • [10] Micro-computed tomography for analysis of urinary calculi
    James C. Williams
    James A. McAteer
    Andrew P. Evan
    James E. Lingeman
    Urological Research, 2010, 38 : 477 - 484