BASIC TECHNICAL PROPERTIES OF A SYSTEM FOR DIRECT ACQUISITION OF DIGITAL INTRAORAL RADIOGRAPHS

被引:51
|
作者
WELANDER, U
NELVIG, P
TRONJE, G
MCDAVID, WD
DOVE, SB
MORNER, AC
CEDERLUND, T
机构
[1] REGAM MED SYST AB, SUNDSVALL, SWEDEN
[2] UNIV TEXAS, HLTH SCI CTR, DEPT DENT DIAGNOST SCI, SAN ANTONIO, TX 78284 USA
[3] HUDDINGE UNIV HOSP, DEPT HOSP PHYS, S-14186 HUDDINGE, SWEDEN
关键词
D O I
10.1016/0030-4220(93)90180-C
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The Sens-A-Ray system for direct digital intraoral radiography may be used with any computer compatible with an IBM PC/AT. The system relies on a charge-coupled device designed for direct conversion of x-ray energy to an electronic signal. It is the first such device for direct acquisition of radiographs. Technical properties of charge-coupled device detectors when exposed to radiation energies in the range of x-rays used in dental radiography have been studied. Even in the absence of light or x-radiation there is a spontaneous generation of charge within a charge-coupled device detector that gives rise to a background signal, a dark current. It was found that the dark current is a linear function of exposure time. The dose response of the charge-coupled device detector was determined at nominal kilovoltages that range from 50 to 90 kVp. The dose response was shown to be a linear function of exposure. The functions for all kVp settings were practically identical. The charge-coupled device detector is more sensitive to x-radiation than conventional dental films and, consequently, its exposure range is more narrow. The signal-to-noise ratio was calculated from the digital radiographs used for the dose response test. The ratio is above 1 0 for exposures higher than about 2 muC/kg. The line spread function was determined from test radiographs of a 10 mum wide slit in a test object of 1.5 mm thick tantalum. After curve fitting, the line spread function could be expressed as the sum of a Gaussian and an exponential function. Presampling modulation transfer functions valid at the detector plane and at an object plane were calculated from fitted data on the line spread function. It is concluded that the Sens-A-Ray system has such technical properties that it may replace conventional film-based systems.
引用
收藏
页码:506 / 516
页数:11
相关论文
共 50 条
  • [1] Physical properties of a system for direct acquisition of digital intraoral radiographs
    Gang Li
    Kazumori Yoshiura
    Xie-Qi Shi
    Ulf Welander
    William D McDavid
    Oral Radiology, 2003, 19 (1) : 22 - 27
  • [2] ELECTRONIC SYSTEM FOR DIGITAL ACQUISITION OF ROTATIONAL PANORAMIC RADIOGRAPHS
    MCDAVID, WD
    DOVE, SB
    WELANDER, U
    TRONJE, G
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1991, 71 (04): : 499 - 502
  • [3] Conventional and predicted Perceptibility Curves for contrast-enhanced direct digital intraoral radiographs
    Yoshiura, K
    Welander, U
    Shi, XQ
    Li, G
    Kawazu, T
    Tatsumi, M
    Okamura, K
    McDavid, WD
    Kanda, S
    DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (04) : 219 - 225
  • [4] A SIMPLE METHOD FOR MEASURING MTF IN DIRECT DIGITAL INTRAORAL RADIOGRAPHY - TECHNICAL NOTE
    MCDAVID, WD
    WELANDER, U
    SANDERINK, GCH
    DOVE, SB
    TRONJE, G
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (06): : 802 - 805
  • [5] CARIES DIAGNOSIS - COMPARING INTRAORAL RADIOGRAPHS AND DIGITAL IMAGES
    SHROUT, M
    RUSSELL, C
    POTTER, B
    POWELL, B
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 91 - 91
  • [6] Evaluation of technical quality of endodontic treatment - reliability of intraoral radiographs
    Eckerbom, M
    Magnusson, T
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1997, 13 (06): : 259 - 264
  • [7] Evaluation of automatic exposure control in a direct digital intraoral system
    Benchimol, D.
    Nasstrom, K.
    Shi, X. Q.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (06) : 407 - 412
  • [8] Comparison of Diagnostic Accuracy of Conventional Intraoral Periapical and Direct Digital Radiographs in Detecting Interdental Bone Loss
    Ashwinirani, S. R.
    Suragimath, Girish
    Jaishankar, H. P.
    Kulkarni, Prasad
    Bijjaragi, Shobha C.
    Sangle, Varsha Ajit
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (02) : ZC35 - ZC38
  • [9] Reliability of marginal bone level measurements on digital panoramic and digital intraoral radiographs
    Hellen-Halme, Kristina
    Lith, Agneta
    Shi, Xie-Qi
    ORAL RADIOLOGY, 2020, 36 (02) : 135 - 140
  • [10] Reliability of marginal bone level measurements on digital panoramic and digital intraoral radiographs
    Kristina Hellén-Halme
    Agneta Lith
    Xie-Qi Shi
    Oral Radiology, 2020, 36 : 135 - 140