Simulation Manikin Modifications for High-Fidelity Training of Advanced Airway Procedures

被引:2
|
作者
Hirsch, Jan
Generoso, Jose R.
Latoures, Renee
Acar, Yahya
Fidler, Richard L.
机构
[1] Univ Calif San Francisco, Dept Anesthesia & Perioperat Care, San Francisco, CA 94143 USA
[2] San Francisco VA Med Ctr, Simulat Ctr, San Francisco, CA USA
关键词
D O I
10.1213/XAA.0000000000000278
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Thoracic anesthesia procedures are challenging to master during anesthesia training. A Laerdal ALS Simulator (R) manikin was modified by adding a bronchial tree module to create fidelity to the fourth generation. After modification, placement of endotracheal tubes up to 8.0 mm is possible by direct laryngoscopy, video laryngoscopy, and fiberoptically; in addition, it allows fiberoptically guided insertion of endobronchial blockers. Insertion of left and right 35-Fr double-lumen tubes permits double-and single-lung ventilation with continuous positive airway pressure and positive end-expiratory pressure. This anatomical modification created a high-fidelity training tool for thoracic anesthesia that has been incorporated into educational curricula for anesthesia.
引用
收藏
页码:268 / 271
页数:4
相关论文
共 50 条
  • [1] Usability evaluation of high-fidelity simulation manikin for cardiopulmonary resuscitation training for medical students
    Silva L.D.B.
    Gonçalves F.T.
    Arantes H.P.
    Garcia R.A.
    Gasparin M.R.F.R.
    dos Reis M.M.
    Andrade A.D.O.
    Pereira A.A.
    Milagre S.T.
    Santos F.P.
    Research on Biomedical Engineering, 2024, 40 (01) : 253 - 264
  • [2] High-Fidelity Simulation for Advanced Cardiac Life Support Training
    Davis, Lindsay E.
    Storjohann, Tara D.
    Spiegel, Jacqueline J.
    Beiber, Kellie M.
    Barletta, Jeffrey F.
    AMERICAN JOURNAL OF PHARMACEUTICAL EDUCATION, 2013, 77 (03)
  • [3] High-Fidelity Simulation Training in Advanced Resuscitation for Pharmacy Residents
    Eng, Amy J.
    Namba, Jennifer M.
    Box, Kevin W.
    Lane, James R.
    Kim, Dennis Y.
    Davis, Daniel P.
    Doucet, Jay J.
    Coimbra, Raul
    AMERICAN JOURNAL OF PHARMACEUTICAL EDUCATION, 2014, 78 (03)
  • [4] The quality of a simulation examination using a high-fidelity child manikin
    Tsai, TC
    Harasym, PH
    Nijssen-Jordan, C
    Jennett, P
    Powell, G
    MEDICAL EDUCATION, 2003, 37 : 72 - 78
  • [5] SIMULATION TRAINING WITH STANDARDIZED PATIENT VERSUS HIGH-FIDELITY MANIKIN INCREASES ACTIVE LEARNING FOR MEDICAL STUDENTS
    Kwon, S. S.
    Krause, R.
    Hayton, A.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 : A128 - A128
  • [6] Light at the end of the tunnel for high-fidelity airway training
    Shimmin, H.
    Muniz, C.
    Willers, J.
    Jones, E.
    ANAESTHESIA, 2018, 73 : 15 - 15
  • [7] High-fidelity simulation training for the primary exam
    Harvey, R.
    Gillan, C.
    Edgar, S.
    ANAESTHESIA, 2013, 68 (08) : 882 - 882
  • [8] Advanced High-Fidelity Autonomy Systems Simulation
    Carrillo, Justin T.
    Cecil, Orie M.
    Monroe, John G.
    Trautz, Andrew C.
    Farthing, Matthew W.
    Bray, Matthew D.
    AUTONOMOUS SYSTEMS: SENSORS, PROCESSING AND SECURITY FOR GROUND, AIR, SEA AND SPACE VEHICLES AND INFRASTRUCTURE 2022, 2022, 12115
  • [9] High-Fidelity Simulation Enhances ACLS Training
    Langdorf, Mark I.
    Strom, Suzanne L.
    Yang, Luanna
    Canales, Cecilia
    Anderson, Craig L.
    Amin, Alpesh
    Lotfipour, Shahram
    TEACHING AND LEARNING IN MEDICINE, 2014, 26 (03) : 266 - 273
  • [10] A comparative study of traditional high-fidelity (manikin-based) simulation and virtual high-fidelity simulations concerning their effectiveness and perception
    Salacinska, Izabela
    Trojnar, Patrycja
    Gebrine, Krisztina eles
    Toro, Viktoria
    Sarvary, Attila
    Wiech, Pawel
    FRONTIERS IN MEDICINE, 2025, 12