THE DEPENDENCE OF THE RESOLVING POWER AND SENSITIVITY OF A DISCRETE ELECTRODE DETECTOR ARRAY ON THE PROXIMITY OF A MICROCHANNEL-PLATE ELECTRON MULTIPLIER

被引:3
|
作者
LANGSTAFF, DP [1 ]
BIRKINSHAW, K [1 ]
机构
[1] UNIV WALES,DEPT PHYS,ABERYSTWYTH SY23 3BZ,DYFED,WALES
关键词
D O I
10.1002/rcm.1290090814
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A detector array has been designed which integrates all pulse sensing, data logging, control and interface circuitry on a single silicon chip. In conjunction with a microchannel-plate electron multiplier (MCP) the array can be used to measure dispersed spectra of ions, electrons and photons (UV and higher energies). In order to increase the sensitivity of the pulse sensing circuitry, non-standard steps are introduced into the fabrication process which increase cost and prototype development time. In the present work it is shown that by reducing the separation between the MCP output and the array to about 4.5 microns an improvement in performance is achieved which should enable the production of high performance devices using a standard fabrication process.
引用
收藏
页码:703 / 706
页数:4
相关论文
共 10 条
  • [1] Microchannel plate electron multiplier calibration using a discrete detector array
    Narayan, DJ
    Langstaff, DP
    Sinha, MP
    Birkinshaw, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 176 (03) : 161 - 166
  • [2] RESOLVING POWER OF A DISCRETE ELECTRODE DETECTOR ARRAY
    BIRKINSHAW, K
    LANGSTAFF, DP
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 136 (01): : 71 - 83
  • [3] MICROCHANNEL-PLATE PHOTOMULTIPLIER WITH LINEAR-ARRAY OF DISCRETE ANODES
    VOLKOV, VP
    GLUKHOVSKOI, BM
    OKHAI, VP
    YAROSHENKO, IF
    BELYANCHENKO, SA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1993, 36 (01) : 133 - 136
  • [4] SELF-SCANNED ANODE ARRAY WITH A MICROCHANNEL PLATE ELECTRON MULTIPLIER - SSANACON
    BROADFOOT, AL
    SANDEL, BR
    APPLIED OPTICS, 1977, 16 (06): : 1533 - 1538
  • [5] Resolving power enhancement of a discrete detector (array) by single event detection
    Sinha, MP
    Langstaff, DP
    Narayan, DJ
    Birkinshaw, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 176 (1-2) : 99 - 102
  • [6] Examination of the spatial-response uniformity of a microchannel-plate detector using a pulsed high-voltage electron gun
    Alumot, D.
    Kroupp, E.
    Fisher, A.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] LOW-PROFILE HIGH-EFFICIENCY MICROCHANNEL-PLATE DETECTOR SYSTEM FOR SCANNING ELECTRON-MICROSCOPY APPLICATIONS
    POSTEK, MT
    KEERY, WJ
    FREDERICK, NV
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (06): : 1648 - 1657
  • [8] LARGE-ENTRY-WINDOW DETECTOR CONSISTING OF A MICROCHANNEL PLATE AND A CHANNEL-TYPE ELECTRON MULTIPLIER
    BELYAEVSKII, OA
    GLADYSHEV, IL
    KOROBOCHKO, YS
    MINEEV, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (05) : 1028 - 1031
  • [9] LOW BACKGROUND-RATE DETECTOR FOR 40-KEV IONS USING A CONVERSION DYNODE AND A MICROCHANNEL-PLATE ELECTRON MULTIPLIER TO REJECT LOW-ENERGY IONS, ELECTRONS, AND PHOTONS
    FRIEDMAN, PG
    BERTSCHE, KJ
    MICHEL, MC
    MORRIS, DE
    MULLER, RA
    TANS, PP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (01): : 98 - 111
  • [10] LARGE-ENTRY-WINDOW DETECTOR CONSISTING OF A MICROCHANNEL PLATE AND A CHANNEL-TYPE ELECTRON MULTIPLIER.
    Belyaevskii, O.A.
    Gladyshev, I.L.
    Korobochko, Yu.S.
    Mineev, V.I.
    Instruments and experimental techniques New York, 1983, 26 (5 pt 1): : 1028 - 1031