NOAA-11 AVHRR VISIBLE AND NEAR-IR INFLIGHT CALIBRATION

被引:149
|
作者
HOLBEN, BN
KAUFMAN, YJ
KENDALL, JD
机构
[1] NASA,GODDARD SPACE FLIGHT CTR,UNIV SPACE RES ASSOCIAT,GREENBELT,MD 20771
[2] SCI SYST APPLICAT INC,GREENBELT,MD 20771
关键词
D O I
10.1080/01431169008955109
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
An inflight calibration method for NOAA-U Advanced Very High Resolution Radiometer (AVHRR) visible and near-infrared bands using desert reflectance is discussed. The results show a decrease in sensor systems response of 22 per cent and 32 per cent for the visible and near-infrared bands respectively, relative to the published preflight calibration. The relative accuracy of the present calibration to the calibration of NOAA-9, published elsewhere, is ±3 per cent. The absolute accuracy is around ±6 per cent. An approximate correction to the Normalized Difference Vegetation Index (NDVI) ratio suggests that an increase of 0.06 is required. © 1990 Taylor & Francis Group, LLC.