THE EFFECT OF TEMPERATURE AND H2S CONTENT ON THE CRACKING RESISTANCE OF A 13-PERCENT CHROMIUM MARTENSITIC STAINLESS-STEEL IN ACIDIFIED NACL

被引:14
|
作者
TURNBULL, A
MAY, AT
机构
[1] Division of Materials Applications, National Physical Laboratory, Teddington
关键词
Hydrogen Ion Concentration - Oil Field Equipment - Tubular Goods - Sodium Chloride;
D O I
10.1016/0010-938X(90)90030-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The cracking resistance of a 13% chromium martensitic stainless steel has been determined, using the slow strain rate technique, as a function of the temperature (23-80°C) and H2S content of acidified NaCl. A clear correlation between relative time-to-failure and sub-surface hydrogen content (Co) has been established at each temperature. However, it is shown that the predominant factor determining cracking is the fractional occupancy of reversible trap sites. A broad correlation has been identified between relative time-to-failure and fractional occupancy of traps irrespective of whether the latter is obtained by varying temperature, H2S content or pH (≤3.6). © 1990.
引用
收藏
页码:657 / 665
页数:9
相关论文
共 50 条