Comparison of Bowel Preparation Depending on Completion Time of Polyethylene Glycol Ingestion and Start Time of Colonoscopy

被引:7
|
作者
Yoon, Jang Hyuk
Park, Dong Il [1 ,3 ]
Shin, Jeong Eun
Kim, Seong Eun [2 ,3 ,4 ]
Jung, Sung Ae [3 ,5 ,6 ]
Lee, Suck Ho [1 ,2 ]
Chang, Dong Kyung [4 ,5 ]
Eun, Chang Soo [2 ,3 ]
Han, Dong Soo [3 ,5 ,6 ]
Kim, Hyun Soo [1 ,2 ,4 ]
Park, Seun Ja [5 ]
Baek, Il Hyun [4 ,6 ]
Jang, Byung Ik [1 ]
Keum, Bora [6 ]
Jeen, Yoon Tae
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Internal Med, Seoul, South Korea
[2] Dankook Univ, Coll Med, Cheonan, South Korea
[3] Ewha Womans Univ, Sch Med, Seoul, South Korea
[4] Hanyang Univ, Coll Med, Seoul, South Korea
[5] Yonsei Univ Wonju, Coll Med, Wonju, South Korea
[6] Hallym Univ, Coll Med, Seoul, South Korea
关键词
Colonoscopy; Polyethylene Glycol (PEG) Solution; Bowel Preparation;
D O I
10.5217/ir.2010.8.1.24
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Polyethylene glycol (PEG) solution is the most widely used bowel preparation agent for colonoscopy because of its safety and efficacy in colon cleansing. It has been hypothesized that the timing of colon preparation may influence the quality of colon cleansing, and therefore affect the diagnostic yield of colonoscopy. The aim of this study was to determine the optimal interval of time between complete ingestion of PEG and performing colonoscopy. Methods: We prospectively enrolled 1,355 patients who had undergone a PEG-based bowel preparation on the day of colonoscopy in 11 tertiary hospitals in Korea between March 2008 and February 2009. All colonoscopies were performed in the afternoon. The start time of PEG ingestion, completion time of PEG ingestion, dose of PEG ingested, start time of colonoscopy, and the quality of bowel cleansing were recorded. Results: There was no difference of cleansing quality of bowel preparation between three groups of less than 7 hours of elapsed time (2= and <3 hours, 3= and <5 hours, 5= and <7 hours). However, group of more than 7 hours of elapsed time presented poor cleansing quality than others (P<0.01). Conclusions: If > 7 hours elapses after ingestion of PEG, the quality of bowel preparation is poor. Therefore, depending on the time colonoscopy is scheduled, the start time of PEG ingestion may need to be adjusted.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [1] Duration of the interval between completion of the bowel preparation and start of the colonoscopy as a better predictor of bowel preparation quality than colonoscopy start time alone
    Yang, Kenneth
    Siddiqui, Ali
    Spechler, Stuart J.
    Cryer, Byron I.
    Davila, Raquel E.
    Harford, William
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB76 - AB76
  • [2] Importance of the Time Interval between Bowel Preparation and Colonoscopy in Determining the Quality of Bowel Preparation for Full-Dose Polyethylene Glycol Preparation
    Kim, Tae Kyung
    Kim, Hyung Wook
    Kim, Su Jin
    Ha, Jong Kun
    Jang, Hyung Ha
    Hong, Young Mi
    Park, Su Bum
    Choi, Cheol Woong
    Kang, Dae Hwan
    GUT AND LIVER, 2014, 8 (06) : 625 - 631
  • [3] Duration between the completion of bowel preparation and the start of colonoscopy predicts bowel preparation quality
    Zad, Mohammadali
    Do, Cuong
    Johnston, Lucy
    Alansari, Mohammed
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 33 : 257 - 257
  • [4] Duration between the completion of bowel preparation and the start of colonoscopy predicts bowel preparation quality
    Zad, M.
    Do, C. N.
    Johnston, L.
    Alansari, M.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 33 : 156 - 157
  • [5] Comparison of one and two-day bowel preparation with polyethylene glycol in pediatric colonoscopy
    Najafi, Mehri
    Fallahi, Gholam Hossein
    Motamed, Farzaneh
    Farahmand, Fatemeh
    Khodadad, Ahmad
    Ghajarzadeh, Mahsa
    Rezaei, Nima
    Mehrabani, Sanaz
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2015, 26 (03): : 232 - 235
  • [6] Comparison of Polyethylene Glycol versus Lactulose Oral Solution for Bowel Preparation prior to Colonoscopy
    Li, Chun-Xia
    Guo, Yan
    Zhu, Yang-Jie
    Zhu, Jian-Ru
    Xiao, Qian-Song
    Chen, Dong-Feng
    Lan, Chun-Hui
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2019, 2019
  • [7] ORAL LACTULOSE IS SUPERIOR TO POLYETHYLENE GLYCOL FOR COLONOSCOPY BOWEL PREPARATION
    Ramos, Josue Aliaga
    Carvalho, Danilo
    Arantes, Vitor
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB146 - AB147
  • [8] Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality
    Siddiqui, Ali A.
    Yang, Kenneth
    Spechler, Stuart J.
    Cryer, Byron
    Davila, Raquel
    Cipher, Daisha
    Harford, William V.
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (03) : 700 - 706
  • [9] The time interval of bowel preparation and start of colonoscopy is more important in determining the quality of bowel cleansing
    Kim, Tae Kyung
    Choi, Cheol Woong
    Kim, Hyung Wook
    Kang, Dae Hwan
    Park, Su Bum
    Kim, Su Jin
    Park, Jin Hyun
    Ha, Jong Kun
    Jang, Hyung Ha
    Hong, Young Mi
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 187 - 187
  • [10] Time Interval Between Purgative Completion and Colonoscopy Start Time Is an Independent Predictor of Bowel Preparation Quality Among Hispanic Patients at a Large County Hospital
    Chan, Michael
    Birnstein, Elliott
    Patel, Nirali
    Chan, Linda
    Laine, Loren
    Kline, Michael
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 : S432 - S432