Determination of benzene, toluene, ethylbenzene and o-xylene in bottled waters by headspace solid-phase microextraction and gas chromatography/mass spectrometry

被引:2
|
作者
Kim, Jong-Hun [1 ]
机构
[1] Jeonju Univ, Dept Environm Hlth Sci, Jeonju 560759, South Korea
来源
ANALYTICAL SCIENCE AND TECHNOLOGY | 2011年 / 24卷 / 02期
关键词
BTEX; bottled water; tap water; GC/MS; SPME;
D O I
10.5806/AST.2011.24.2.119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The amount of benzene, toluene, ethylbenzene, and o-xylene (BTEX) in 30 kinds of bottled waters purchased from market and 9 kinds of tap waters from home were determined using headspace solid phase microextraction (HS-SPME). The sample was stirred at 1200 RPM G for 4 min using a magnetic bar with 100 mu m PDMS as adsorbent for BTEX. Then it was desorbed from the fiber for 1 min at room temperature. Quantitation was achieved using standard calibration method. The limit of detection was determined as benzene 0.39 (+/- 0.04) ng/mL, toluene 0.08 (+/- 0.04) ng/mL, ethylbenzene 0.04 (+/- 0.01) ng/mL, and o-xylene 0.05 (+/- 0.02) ng/mL. Benzene and o-xylene were not detected in any samples, but toluene was detected in 11 samples, and ethylbenzene was detected just in 3 samples among 30 investigated bottled waters. The concentration range of investigated materials for toluene and o-xylene were 0.24 (+/- 0.09)-2.95 (+/- 0.08) ng/mL, 0.08 (+/- 0.06)-0.93 (+/- 0.10) ng/mL, respectively.
引用
收藏
页码:119 / 126
页数:8
相关论文
共 50 条