THE MECHANISM OF WHITE CELL REDUCTION BY SYNTHETIC-FIBER CELL FILTERS

被引:19
|
作者
CALLAERTS, AJ
GIELIS, ML
SPRENGERS, ED
MUYLLE, L
机构
[1] ORGANON TEKNIKA BV,RES UNIT,BOSEIND 15,5200 AB BOXTEL,NETHERLANDS
[2] BLOOD TRANSFUS CTR ANTWERP,ANTWERP,BELGIUM
[3] BELGIAN RED CROSS,EGEGEM,BELGIUM
关键词
D O I
10.1046/j.1537-2995.1993.33293158045.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The mechanism of white cell (WBC) retention by synthetic fiber-based WBC filters was studied. Filters were made of nonwoven fleece prepared from polyester, surface-modified polyester, or polypropylene fibers. Human platelet concentrates were filtered through experimental filters consisting of 8 to 54 layers of nonwoven fleece with mean pore sizes from 7.3 to 14.2 mum. Filters made of fleece of smaller pore size removed WBCs less effectively than filters with larger-pore fleece. Retention of lymphocytes and granulocytes gradually dropped to 0 percent as increasing loads were applied to the filters. The maximal retention capacity for these cell types (i.e., the number of cells retained when ''saturating'' numbers of WBCs were applied) was proportional to the number of layers of filter material used. Platelet retention did not correlate with WBC retention. Depth filtration, rather than mechanical sieving, seems to be the principal means of WBC removal by nonwoven fiber filters. A low initial number of WBCs in the component to be filtered is important for successful WBC filtration.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 50 条
  • [1] LOW RETENTION OF WHITE CELL FRAGMENTS BY POLYESTER FIBER WHITE CELL-REDUCTION PLATELET FILTERS
    RAMOS, RR
    CURTIS, BR
    DUFFY, BF
    CHAPLIN, H
    TRANSFUSION, 1994, 34 (01) : 31 - 34
  • [2] SYNTHETIC-FIBER RECLAMATION
    LONGWORTH, B
    TEXTILE INSTITUTE AND INDUSTRY, 1977, 15 (08): : 282 - 282
  • [3] A SYNTHETIC-FIBER - UNTAPPED
    DAS, AK
    COLOURAGE, 1991, 38 (01): : 40 - 42
  • [4] POLICY FOR SYNTHETIC-FIBER
    不详
    COLOURAGE, 1979, 26 (25): : 1 - 1
  • [5] EFFECTIVENESS OF 2 SYNTHETIC-FIBER FILTERS FOR REMOVING WHITE CELLS FROM AS-1 RED-CELLS
    PIKUL, FJ
    FARRAR, RP
    BORIS, MB
    ESTOK, L
    MARLO, D
    WILDGEN, M
    CHAPLIN, H
    TRANSFUSION, 1989, 29 (07) : 590 - 595
  • [6] SYNTHETIC-FIBER GRANULOMA
    LUEDER, GT
    ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (07) : 848 - 849
  • [7] A comparison of different filters for white cell reduction
    Yaprak, I
    Yercen, N
    Aksit, S
    Akdeniz, F
    Turker, M
    Caglayan, S
    TURKISH JOURNAL OF PEDIATRICS, 1998, 40 (01) : 89 - 95
  • [8] SYNTHETIC-FIBER IMPLANT SCAM
    LEPAW, MI
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 1979, 18 (06) : 468 - 471
  • [9] SYNTHETIC-FIBER GRANULOMA OF THE CONJUNCTIVA
    SHIELDS, JA
    AUGSBURGER, JJ
    STECHSCHULTE, J
    REPKA, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 99 (05) : 598 - 600
  • [10] ELECTRON-MICROSCOPIC EXAMINATION OF WHITE CELL REDUCTION BY 4 WHITE CELL-REDUCTION FILTERS
    STENEKER, I
    VANLUYN, MJA
    VANWACHEM, PB
    BIEWENGA, J
    TRANSFUSION, 1992, 32 (05) : 450 - 457