DOBUTAMINE STRESS-TESTING IN CHRONIC HEART FAILURE-DOSE-RESPONSE EFFECTS ASSESSED BY ECHO-DOPPLER

被引:0
|
作者
GUY, S [1 ]
SILKE, B [1 ]
机构
[1] QUEENS UNIV BELFAST, DEPT THERAPEUT & PHARMACOL, WHITLA MED BLDG, 97 LISBURN RD, BELFAST BT9 7BL, ANTRIM, NORTH IRELAND
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In patients with cardiac failure, data on haemodynamic function at rest may indicate impaired cardiac function but do not assess the capacity of the heart to respond to stress which may be useful in determining prognosis. Inotropic challenge with dobutamine has been shown to be at least as effective as exercise testing in assessing cardiac pumping capability. One of the limitations of dobutamine stress testing has been the need for invasive haemodynamic measurements. A new non-imaging echo-Doppler cardiac output device, incorporating the principle of attenuated compensation volume flow (ACVF), has been shown to be accurate, reproducible and useful in pharmacodynamic studies. In this study we examined the dose-response effects of dobutamine in 8 patients with chronic heart failure. Dobutamine was infused at 2, 5, 10 and 15-mu-g/kg/min with the dose being increased at 5 minute intervals and haemodynamics being determined (using the echo-doppler) in the final 2 minutes of infusion. Our results were comparable to previous studies. There were dose-related increases in heart rate (P < 0.05), cardiac output (P < 0.05), and cardiac power output (work done by the heart per unit time) (P < 0.05). Systolic blood pressure increased (P < 0.001) and there were modest increases in mean arterial blood pressure without change in diastolic blood pressure. Time averaged mean velocity increased significantly with a trend to increase in flow acceleration. Three patients developed arrythymias during the early recovery period. The echo Doppler attentuated compensated volume flow method of determining haemodynamics proved useful in view of the high incidence of dysrhythmia we feel that dobutamine testing in severe heart failure should be employed cautiously.
引用
收藏
页码:S62 / S68
页数:7
相关论文
共 27 条
  • [1] Echo-doppler characteristics of incipient chronic heart failure in the elderly
    Dzizinsky, AA
    Pogodin, KV
    KARDIOLOGIYA, 1999, 39 (05) : 36 - 39
  • [2] DOSE-RESPONSE EFFECTS OF NICARDIPINE ASSESSED USING AN ECHO-DOPPLER ULTRASOUND CARDIAC-OUTPUT DEVICE
    ZEZULKA, AV
    SILKE, B
    VERMA, SP
    SHARMA, SK
    TAYLOR, SH
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1988, 25 (05) : P639 - P639
  • [3] Utility of echo-Doppler and BNP in determining hemodynamic profile in chronic heart failure patients
    Le Rovere, MT
    Capomolla, S
    Caresa, M
    Aiolfi, E
    Nori, A
    Caporotondi, A
    Guazzotti, GP
    Paganini, V
    Rossi, A
    Cobelli, F
    Maugeri, FS
    CIRCULATION, 2004, 110 (17) : 714 - 714
  • [4] ECHO-DOPPLER CHARACTERISTICS OF SILENT MITRAL REGURGITATION IN PATIENTS WITH CHRONIC CONGESTIVE-HEART-FAILURE
    VASSOLO, M
    MAURER, G
    CERCEK, B
    SIEGEL, R
    PALMAS, W
    SHAH, PK
    CIRCULATION, 1992, 86 (04) : 256 - 256
  • [5] HIGH-DOSE NITRATE THERAPY IN PATIENTS WITH SEVERE CONGESTIVE-HEART-FAILURE - ACUTE HEMODYNAMIC AND ECHO-DOPPLER EFFECTS
    RUSCONI, C
    FAGGIANO, P
    SABATINI, T
    GHIZZONI, G
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1991, 4 (01): : 3 - 7
  • [6] Echo-Doppler and clinical evaluations to define hemodynamic profile in patients with chronic heart failure: accuracy and influence on therapeutic management
    Capomolla, S
    Ceresa, M
    Pinna, G
    Maestri, R
    La Rovere, MT
    Febo, O
    Rossi, A
    Paganini, V
    Caporotondi, A
    Guazzotti, G
    Gnemmi, M
    Mortara, A
    Cobelli, F
    EUROPEAN JOURNAL OF HEART FAILURE, 2005, 7 (04) : 624 - 630
  • [7] In patients with chronic heart failure echo-Doppler monitoring is more accurate than physical examination to detect severe hemodynamic alterations
    Capomolla, S
    Febo, O
    Guazzotti, G
    Caporotondi, A
    Gnemmi, M
    Mortara, A
    Cobelli, F
    Pinna, G
    Maestri, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 205A - 205A
  • [8] Two simple echo-Doppler measurements can accurately identify pulmonary hypertension in the large majority of patients with chronic heart failure
    Lanzarini, L
    Fontana, A
    Campana, C
    Klersy, C
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (06): : 745 - 754
  • [9] HEMODYNAMIC DOSE-RESPONSE EFFECTS OF DOBUTAMINE AND AMRINONE IN ACUTE HEART-FAILURE
    MIDTBO, KA
    SILKE, B
    VERMA, SP
    REYNOLDS, G
    TAYLOR, SH
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 22 (02) : P209 - P209
  • [10] Safety and accuracy of cardiac magnetic resonance imaging combined with low-dose dobutamine stress-testing in patients with congenital heart disease
    Saskia E Luijnenburg
    Daniëlle Robbers-Visser
    Jochem van den Berg
    Jolien W Roos-Hesselink
    Adriaan Moelker
    Willem A Helbing
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)