Determination of urea in canned foods by high performance liquid chromatography-fluorescence detection coupled with precolumn derivatization

被引:5
|
作者
Zeng Qi [1 ]
Zhang Jin [1 ]
Xu Dunming [1 ]
Zhang Zhigang [1 ]
Ke Zhicheng [1 ]
机构
[1] Xiamen Entry Exit Inspect & Quarantine Bur, Xiamen 361026, Peoples R China
关键词
high performance liquid chromatography (HPLC); fluorescence detection (FLD); urea; canned food; xanthydrol;
D O I
10.3724/SP.J.1123.2014.08024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of urea residue in canned foods by high performance liquid chromatography-fluorescence detection (HPLC-FLD) coupled with precolumn derivatization was established. The sample (5.0 g), including canned edible fungi, fruit, vegetable, fish, and meat was extracted with 20 mL 1% (v/v) acetic acid solution. The extract was centrifuged, filtrated, and then derivatized with xanthydrol. The analysis was completed with HPLC-FLD. A good linear relationship was obtained in the range of 0.1 - 500 mg/L with the correlation coefficients more than 0.999 5. The average recoveries of urea spiked at 0.001 - 30 g/kg levels in five kinds of canned foods ranged from 80.2% to 109.7% with the RSDs of 2.05% - 6.53%. The limit of detection (LOD) was 0.5 mg/kg, and the limit of quantitation (LOQ) was 1.0 mg/kg. The proposed procedure was then applied to the analysis of 168 real samples collected from Xiamen, Fujian Province, China. The existence of urea was found in three pork cans with contents of 10.6, 62.1 and 2.6 mg/kg, respectively. The method is stable, reliable, simple and suitable for the determination of urea in canned foods, and has great potential for routine analysis in foodstuffs.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 12 条
  • [1] Determination of urea using high-performance liquid chromatography with fluorescence detection after automated derivatisation with xanthydrol
    Clark, Shona
    Francis, Paul S.
    Conlan, Xavier A.
    Barnett, Neil W.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) : 207 - 213
  • [2] Accurate analysis of urea in milk and milk powder by isotope dilution gas chromatography-mass spectrometry
    Dai, Xinhua
    Fang, Xiang
    Su, Fuhai
    Yang, Mengrui
    Li, Hongmei
    Zhou, Jian
    Xu, Ruifeng
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1634 - 1638
  • [3] Deng H P, 2001, CHINESE J HLTH LAB T, V11, P591
  • [4] Qi G Y, 2008, CHINESE J HLTH LAB T, V18, P2397
  • [5] Potentiometric biosensor for urea determination in milk
    Trivedi, U. B.
    Lakshminarayana, D.
    Kothari, I. L.
    Patel, N. G.
    Kapse, H. N.
    Makhija, K. K.
    Patel, R. B.
    Panchal, C. J.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) : 260 - 266
  • [6] Wang X J, 2009, SCIENCE, V30, P317
  • [7] Wang YuBo, 2011, China Dairy Industry, V39, P50
  • [8] [王祖翔 Wang Zuxiang], 2012, [分析测试学报, Journal of Instrumental Analysis], V31, P593
  • [9] Wei F, 2006, FOOD ENG, P58
  • [10] Xing J.T., 2011, LIQUOR MAKING SCI TE, V3, P104