A RADIOCHROMIC FILM DOSIMETER FOR GAMMA-RADIATION IN THE ABSORBED-DOSE RANGE 0.1-10-KGY

被引:0
|
作者
KHAN, HM [1 ]
FARAHANI, M [1 ]
MCLAUGHLIN, WL [1 ]
机构
[1] NATL INST STAND & TECHNOL,CTR RADIAT RES,GAITHERSBURG,MD 20899
来源
RADIATION PHYSICS AND CHEMISTRY | 1991年 / 38卷 / 04期
关键词
D O I
暂无
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A commercially available leuco-dye film (FWT-63-02), having a thickness of 0.55 mm, has been investigated spectrophotometrically for its characteristics as a radiochromic dosimeter and for its potential use in food-irradiation applications. The gamma-ray irradiation of the nearly colorless, transparent film induces blue color with an absorption maximum at 600 nm. The increase in absorbance at 600 nm per unit thickness of film (DELTA-A mm-1) is linear with dose in the dose range up to 8 kGy, with a slope of 0.91 mm-1.kGy-1. After a modest additional increase during the first day following irradiation, the radiation-induced color is stable when stored at room temperature at least for 5 weeks. The response slope is 16% higher when stored at 60-degrees-C, however, after the initial 1-day increase it is stable for several weeks when stored at that temperature. The response of the dosimeter is independent of dose rate in the range 0.5-170 Gy min-1.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 38 条
  • [1] A cyanocobalamin dosimeter for monitoring gamma-radiation doses of 0.1-2 kGy
    Maged, AF
    Hamza, MSA
    Saad, EA
    RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (02): : 179 - 181
  • [2] EXPERIMENTAL STUDY OF SPATIAL ABSORBED-DOSE FIELDS OF REACTOR GAMMA-RADIATION IN A POLYETHYLENE SAMPLE
    BRISKMAN, BA
    SAVINA, VP
    SOVIET ATOMIC ENERGY, 1968, 24 (06): : 694 - &
  • [3] SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS
    MCLAUGHLIN, WL
    YUNDONG, C
    SOARES, CG
    MILLER, A
    VANDYK, G
    LEWIS, DF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01): : 165 - 176
  • [4] TEMPERATURE AND RELATIVE-HUMIDITY DEPENDENCE OF RADIOCHROMIC FILM DOSIMETER RESPONSE TO GAMMA-RADIATION AND ELECTRON-RADIATION
    MCLAUGHLIN, WL
    PUHL, JM
    MILLER, A
    RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6): : 1227 - 1233
  • [5] FILM ABSORBED-DOSE DETECTOR OF PHOTON AND ELECTRON-RADIATION
    GENERALOVA, VV
    PONOMAREV, AN
    MEASUREMENT TECHNIQUES, 1979, 22 (07) : 859 - 861
  • [6] ABSORBED-DOSE OF PULSE ELECTRON-BEAM WITH POLYETHYLENE FILM DOSIMETER AND COMPARISON WITH OTHER FILM DOSIMETERS
    CHEN, WX
    LU, GX
    JIA, HS
    RADIATION PHYSICS AND CHEMISTRY, 1983, 22 (06): : 1066 - 1067
  • [7] Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film
    Hermida-Lopez, M.
    Luedemann, L.
    Fluehs, A.
    Brualla, L.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S734 - S734
  • [8] Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 10 keV-18 MeV
    Hermida-Lopez, M.
    Luedemann, L.
    Sauerwein, W.
    Brualla, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 9 - 9
  • [9] ABSORBED DOSE MEASUREMENT WITH A CALORIMETER IN A PULSED GAMMA-RADIATION FIELD
    KALLMEYER, DH
    KOHN, O
    ROOSE, UJ
    ATOMKERNENERGIE, 1974, 24 (03): : 203 - 207