AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF SULFITE IN THE PRESENCE OF A HIGH-CONCENTRATION OF THIOSULFATE

被引:13
|
作者
COSANO, JS [1 ]
DECASTRO, MDL [1 ]
VALCARCEL, M [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
FLOW SYSTEM; SPECTROPHOTOMETRY; SULFITE; ONLINE DILUTION; THIOSULPHATE/SULPHITE RATIOS;
D O I
10.1016/0003-2670(94)00451-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A spectrophotometric method for the determination of sulphite in the presence of up to 200-fold of thiosulphate is proposed. The derivatizing reaction, which is based on the decoloration of p-rosaniline in neutral or slightly basic medium, is developed in an unsegmented flow system. A linear calibration range between 1 and 20 mu g ml(-1) was obtained, with a relative standard deviation of 1.5% and sampling frequency of 40 h(-1). The method has been applied to the determination of the analyte in samples from an ammonium thiosulphate production plant, where the concentration of sulphite is the quality parameter. The concentration of sulphite and thiosulphate in these samples [0.2-1.0% and 50-60% (w/w), respectively] makes necessary a 1:1000 on-line dilution, and the use of peak-width measurements. In these working conditions the linear range was 2.7-20.0 g l(-1) and the R.S.D. values ranged between 1.3 and 2.8%, depending on the constant absorbance value selected for measurement. The sampling frequency was 8 h(-1).
引用
收藏
页码:269 / 274
页数:6
相关论文
共 50 条