PRESSURE-DROP CORRELATIONS AND SCALE-UP OF SIZE EXCLUSION CHROMATOGRAPHY WITH COMPRESSIBLE PACKINGS

被引:29
|
作者
MOHAMMAD, AW [1 ]
STEVENSON, DG [1 ]
WANKAT, PC [1 ]
机构
[1] PURDUE UNIV,SCH CHEM ENGN,W LAFAYETTE,IN 47907
关键词
D O I
10.1021/ie00002a016
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Pressure drop measurements were made for compressible gel packings Sephadex G-25 and G-100. A critical velocity at which pressure drop kept increasing was observed. Correlations were developed for pressure drop. Measurements of the chromatographic separation obtained for separating bovine serum albumin and nickel nitrate were correlated as measurements of H. A scaling procedure which keeps separation, pressure drop, and feed throughput constant was developed for each packing. The procedure and results for G-25 are similar to those developed previously for rigid packings. The use of smaller diameter packings can greatly reduce the amount of packing required. For G-100, which is quite compressible, the scaling procedure was different. Results of the scaling analysis for G-100 showed that there is little advantage to decreasing the particle size with very compressible packings.
引用
收藏
页码:549 / 561
页数:13
相关论文
共 50 条
  • [1] Mathematical modeling and scale-up of size-exclusion chromatography
    Li, ZG
    Gu, YS
    Gu, TY
    BIOCHEMICAL ENGINEERING JOURNAL, 1998, 2 (02) : 145 - 155
  • [2] PRESSURE-DROP IN STRUCTURED PACKINGS
    BRAVO, JL
    ROCHA, JA
    FAIR, JR
    HYDROCARBON PROCESSING, 1986, 65 (03): : 45 - 49
  • [3] DETERMINATION OF THE SPECIFIC PRESSURE-DROP IN PACKINGS
    WINKLER, K
    GRABBERT, G
    STANEK, V
    CHEMISCHE TECHNIK, 1985, 37 (03): : 104 - 107
  • [4] FLOODING AND PRESSURE-DROP IN STRUCTURED PACKINGS
    KISTER, HZ
    GILL, DR
    CHEMICAL ENGINEER-LONDON, 1992, (525): : S7 - S9
  • [5] PRESSURE-DROP AND FLOODING POINT IN PACKINGS
    BORNHUTTER, K
    MERSMANN, A
    CHEMIE INGENIEUR TECHNIK, 1992, 64 (03) : 304 - 305
  • [6] PRESSURE-DROP IN CERAMIC STRUCTURED PACKINGS
    URESTIMELENDEZ, J
    ROCHA, JA
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1993, 32 (10) : 2247 - 2253
  • [7] EVALUATION OF THE PRESSURE-DROP OF IRRIGATED PACKINGS
    MACKOWIAK, J
    STAUB REINHALTUNG DER LUFT, 1990, 50 (12): : 455 - 463
  • [8] A framework for the prediction of scale-up when using compressible chromatographic packings
    Tran, Richard
    Joseph, John R.
    Sinclair, Andrew
    Bracewell, Daniel
    Zhou, Yuhong
    Titchener-Hooker, Nigel J.
    BIOTECHNOLOGY PROGRESS, 2007, 23 (02) : 413 - 422
  • [9] A generic framework for the prediction of scale-up when using compressible chromatographic packings
    Tran, R
    Joseph, J
    Sinclair, A
    Zhou, Y
    Titchener-Hooker, N
    JOURNAL OF BIOTECHNOLOGY, 2005, 118 : S56 - S56
  • [10] THE LIMITS OF APPLICABILITY OF PRESSURE-DROP CORRELATIONS
    PUNCOCHAR, M
    DRAHOS, J
    CERMAK, J
    CHEMICAL ENGINEERING SCIENCE, 1990, 45 (09) : 2994 - 2998