Precision and accuracy of gas chromatography-combustion isotope ratio mass spectrometry are investigated for sample levels down to about 5 pmol C in fatty acid methyl ester mixtures spanning 1000-fold in concentration. Precision and accuracy of isotope ratios diverge rapidly for conventional summation methods, and become unusable below 30 pmol material on column. At lower levels, mean isotope ratios were statistically different from reference values indicating bias as well as poor precision. In contrast, curve fitting, using the exponentially modified Gaussian line shape, gives improved precision for most peaks and useful results down to 3 pmol. The curve-fitting algorithm was also less sensitive to signal integration time than the summation method. These data indicate that curve fitting may be the method of choice for integration of noisy data when high-precision isotope ratios are desired.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [1] HIGH-PRECISION LIQUID CHROMATOGRAPHY-COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY
    CAIMI, RJ
    BRENNA, JT
    ANALYTICAL CHEMISTRY, 1993, 65 (23) : 3497 - 3500
  • [2] ACCURACY AND PRECISION OF GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY FOR STABLE CARBON-ISOTOPE RATIO MEASUREMENTS
    WONG, WW
    HACHEY, DL
    ZHANG, S
    CLARKE, LL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (11) : 1007 - 1011
  • [3] PERFORMANCE AND OPTIMIZATION OF A COMBUSTION INTERFACE FOR ISOTOPE RATIO MONITORING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    MERRITT, DA
    FREEMAN, KH
    RICCI, MP
    STUDLEY, SA
    HAYES, JM
    ANALYTICAL CHEMISTRY, 1995, 67 (14) : 2461 - 2473
  • [4] DETERMINATION OF (C-13)UREA ENRICHMENT BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY ISOTOPE RATIO MASS-SPECTROMETRY
    BEYLOT, M
    DAVID, F
    KHALFALLAH, Y
    NORMAND, S
    LARGE, V
    BRUNENGRABER, H
    BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (08) : 510 - 513
  • [5] DETECTION OF VEGETABLE OIL ADULTERATION USING GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY
    WOODBURY, SE
    EVERSHED, RP
    ROSSELL, JB
    GRIFFITH, RE
    FARNELL, P
    ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2685 - 2690
  • [6] Low Temperature Catalytic Combustion Reactors for High Precision Carbon Isotope Measurements in Gas Chromatography Combustion Isotope Ratio Mass Spectrometry
    Tobias, Herbert J.
    Jones, Andrew
    Spanjers, Charlie
    Bowers, Larry
    Brenna, J. Thomas
    ANALYTICAL CHEMISTRY, 2019, 91 (04) : 2901 - 2907
  • [7] GAS-CHROMATOGRAPHY WITH MASS-SPECTROMETRY OR ISOTOPE-RATIO MASS-SPECTROMETRY IN STUDYING THE GEOGRAPHICAL ORIGIN OF HEROIN
    DESAGE, M
    GUILLUY, R
    BRAZIER, JL
    CHAUDRON, H
    GIRARD, J
    CHERPIN, H
    JUMEAU, J
    ANALYTICA CHIMICA ACTA, 1991, 247 (02) : 249 - 254
  • [8] HIGH-SENSITIVITY TRACER DETECTION USING HIGH-PRECISION GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY AND HIGHLY ENRICHED [U-C-13]-LABELED PRECURSORS
    GOODMAN, KJ
    BRENNA, JT
    ANALYTICAL CHEMISTRY, 1992, 64 (10) : 1088 - 1095
  • [9] HIGH-PRECISION GAS ISOTOPE RATIO MASS-SPECTROMETRY - RECENT ADVANCES IN INSTRUMENTATION AND BIOMEDICAL APPLICATIONS
    BRENNA, JT
    ACCOUNTS OF CHEMICAL RESEARCH, 1994, 27 (11) : 340 - 346
  • [10] MEASUREMENT OF MUSCLE PROTEIN FRACTIONAL SYNTHETIC RATE BY CAPILLARY GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY
    YARASHESKI, KE
    SMITH, K
    RENNIE, MJ
    BIER, DM
    BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (10) : 486 - 490