Relationship of Normal Aortic Valve Cusp Dimensions: A Tool to Optimize Cusp Reconstruction Valvuloplasty

被引:4
|
作者
Subramanian, Sujata [1 ]
Tikhomirov, Vsevolod [1 ]
Bharati, Saroja [1 ]
EiZein, Chawki [1 ]
Roberson, David [1 ]
Ilbawi, Michel N. [1 ]
机构
[1] Advocate Childrens Hosp, Dept Pediat Cardiac Surg & Pediat Cardiol, 4440 W 95th St, Oak Lawn, IL 60453 USA
关键词
aortic valvuloplasty; cusp extension technique; aortic valve; valvuloplasty;
D O I
10.1053/j.semtcvs.2015.08.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Outcomes of surgical aortic valvuloplasty hinge primarily on optimal leaflet design. Imprecise valve reconstruction can result in insufficiency or stenosis. Predicting postrepair leaflet parameters from pre- or intraoperative readily measurable valve dimensions could result in improved reconstruction. This study analyzes the relationships between different parameters of the normal aortic valve to establish a method of deriving the optimal dimensions of the reconstructed leaflet following valvuloplasty. Morphologic analysis of the normal aortic valve was performed on 50 autopsy specimens. The following parameters were measured: circumference at ventriculoaortic junction, intercommissural circumferential distance (IC), commissural height, leaflet free-margin length (L1—length of the free margin of each leaflet), cusp attachment length (L2—cusp attachment length at the ventriculoaortic junction), and leaflet height (A—ie, the vertical or cephalocaudal distance along the convex surface of the leaflet from the midpoint of the leaflet free margin to the midpoint of the cusp attachment). Univariate linear regression analysis was used to test the interdependence of leaflet dimensions. The leaflet free-margin length L1 correlated strongly with the corresponding IC: r = 0.74, 0.81, and 0.79 for noncoronary, right coronary, and left coronary leaflets, respectively; P = 0.000. Leaflet height A and cusp attachment length L2 also correlated well with the corresponding IC: A-IC, r = 0.56, 0.74, and 0.66; and L2-IC, r = 0.78, 0.85, and 0.80 for noncoronary, right coronary, and left coronary cusps respectively; P = 0.000. Parameters required to construct an aortic valve leaflet can be reliably derived from the IC, which can be easily measured perioperatively. Using this as a basis for leaflet reconstruction might optimize the leaflet graft design process, compensate for pathologic variations in aortic annulus size and commissural height, and could result in better coaptation of the valve leaflets. © 2016 Elsevier Inc.
引用
收藏
页码:521 / 527
页数:7
相关论文
共 50 条
  • [1] Aortic cusp extension valvuloplasty for rheumatic aortic valve disease: Midterm results
    Grinda, JM
    Latremouille, C
    Berrebi, AJ
    Zegdi, R
    Chauvaud, S
    Carpentier, AF
    Fabiani, JN
    Deloche, A
    ANNALS OF THORACIC SURGERY, 2002, 74 (02): : 438 - 443
  • [2] Valvuloplasty for aortic valve regurgitation resulting from cusp prolapse.
    Nagamine S.
    Shinozaki S.
    Ohsaka K.
    Kakihata H.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2001, 49 (3): : 175 - 177
  • [3] Avulsion of an Aortic Cusp During Aortic Balloon Valvuloplasty
    Hadjimiltiades, Stavros
    Ziakas, Antonis
    Kazinakis, George
    Nikolaidou, Chrysovalantou
    Anastasiadis, Kyriakos
    Karvounis, Haralambos
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02) : E15 - E16
  • [4] Pediatric aortic valve repair: Any development in the material for cusp extension valvuloplasty?
    Hu, Kelli
    Siddiqi, Umar
    Lee, Brian
    Pena, Emily
    Schulz, Kelci
    Vogel, Maggie
    Combs, Pamela
    El-Zein, Chawki
    Ilbawi, Michel
    Vricella, Luca
    Hibino, Narutoshi
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (11) : 4054 - 4060
  • [5] Aortic valve cusp vessel density: Relationship with tissue thickness
    Weind, KL
    Ellis, CG
    Boughner, DR
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (02): : 333 - 340
  • [6] Aortic Valvuloplasty for Cusp Perforation Caused by Kawasaki Disease
    Yamada, Yukiko
    Shikata, Fumiaki
    Yamamoto, Ryuhei
    Numata, Ryusuke
    Yasukochi, Satoshi
    Takeuchi, Takamasa
    INDIAN JOURNAL OF PEDIATRICS, 2021, 88 (04): : 405 - 405
  • [7] Aortic cusp extension valvuloplasty: repair with an extracellular patch
    Przybylski, Roman
    Pawlak, Szymon
    Sliwka, Joanna
    Urlik, Maciej
    Maruszewski, Marcin
    Kukulski, Tomasz
    Nozynski, Jerzy
    Zembala, Marian
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2015, 12 (04): : 314 - 317
  • [8] Aortic Valvuloplasty for Cusp Perforation Caused by Kawasaki Disease
    Yukiko Yamada
    Fumiaki Shikata
    Ryuhei Yamamoto
    Ryusuke Numata
    Satoshi Yasukochi
    Takamasa Takeuchi
    Indian Journal of Pediatrics, 2021, 88 : 405 - 405
  • [9] BICUSPID AORTIC VALVE WITH RUPTURE OF CUSP
    FLYTHE, WH
    WREN, JC
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1945, 127 (03): : 156 - 157
  • [10] Cusp repair in aortic valve reconstruction:: Does the technique affect stability?
    Aicher, Diana
    Langer, Frank
    Adam, Oliver
    Tscholl, Dietmar
    Lausberg, Henning
    Schaefers, Hans-Joachim
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (06): : 1533 - 1539