Geant4 simulation of a scintillator-lead shashlik calorimeter with a SiPM readout

被引:0
|
作者
Berra, A. [1 ,2 ]
机构
[1] Univ Insubria, Como, Italy
[2] INFN, Sez Milano Bicocca, Milan, Italy
关键词
D O I
10.1393/ncc/i2011-10977-7
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Shashlik calorimeters are sampling calorimeters which, in the last 20 years, have been used in many high-energy experiments: relatively cheap, they can be easily segmented and built in a large variety of geometries and they guarantee energy resolutions comparable to the ones achievable with homogeneous calorimeters. This article presents the complete optical simulation of a prototype of a scintillator-lead shashlik calorimeter with silicon photomultipliers readout, characterized in terms of linearity, energy and spatial resolution. The simulation has been used to explain and validate the experimental data, obtained on the PS-T9 beamline at CERN, using electrons in the 1-7 GeV energy range.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 50 条
  • [1] Silicon Photomultipliers as a Readout System for a Scintillator-Lead Shashlik Calorimeter
    Berra, A.
    Bolognini, D.
    Bonvicini, V.
    Bosisio, L.
    Cauz, D.
    Ciano, S.
    Driutti, A.
    Hasan, S.
    Iugovaz, D.
    Lietti, D.
    Mascagna, V.
    Mattera, A.
    Pauletta, G.
    Penzo, A.
    Piemonte, C.
    Prest, M.
    Rashevskaya, I.
    Reia, S.
    Scarpino, F.
    Vallazza, E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1297 - 1307
  • [2] Characterization of a DAQ system for the readout of a SiPM based shashlik calorimeter
    Berra, A.
    Bonvicini, V.
    Bosisio, L.
    Lietti, D.
    Penzo, A.
    Prest, M.
    Rabaioli, S.
    Rashevskaya, I.
    Vallazza, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 422 - 430
  • [3] Geant4 simulations of the lead fluoride calorimeter
    Savchenko, A. A.
    Tishchenko, A. A.
    Dabagov, S. B.
    Anastasi, A.
    Venanzoni, G.
    Strikhanov, M. N.
    Basti, A.
    Bedeschi, F.
    Bartolini, M.
    Cantatore, G.
    Cauz, D.
    Corradi, G.
    Di Sciascio, G.
    Di Stefano, R.
    Driutti, A.
    Escalante, O.
    Ferrari, C.
    Fioretti, A.
    Gabbanini, C.
    Gioiosa, A.
    Hampai, D.
    Iacovacci, M.
    Karuza, M.
    Liedl, A.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Moricciani, D.
    Pauletta, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 402 : 256 - 262
  • [4] A TOWER STRUCTURED SCINTILLATOR-LEAD PHOTON CALORIMETER USING A NOVEL FIBER OPTICS READOUT SYSTEM
    FESSLER, H
    FREUND, P
    GEBAUER, J
    GLAS, JM
    PRETZL, KP
    SEYBOTH, P
    SEYERLEIN, J
    THEVENIN, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 228 (2-3): : 303 - 308
  • [5] Scintillator tile hadron calorimeter with novel SiPM readout
    Danilov, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 451 - 456
  • [6] Geant4 simulation of optical photon transport in scintillator tile with direct readout by silicon photomultiplier
    Korpachev, S.
    Chadeeva, M.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS, 2017, 798
  • [7] TOWER STRUCTURED SCINTILLATOR-LEAD PHOTON CALORIMETER USING A NOVEL FIBER OPTICS READOUT SYSTEM.
    Fessler, H.
    Freund, P.
    Gebauer, J.
    Glas, J.M.
    Pretzl, K.P.
    Seyboth, P.
    Seyerlein, J.
    Thevenin, J.C.
    Nuclear instruments and methods in physics research, 1985, 228 (2-3): : 303 - 308
  • [8] SEGMENTED SCINTILLATOR-LEAD PHOTON CALORIMETER USING A DOUBLE WAVELENGTH SHIFTER OPTICAL READOUT SYSTEM.
    Fent, J.
    Fessler, H.
    Freund, P.
    Gebauer, H.J.
    Polakos, P.
    Pretzl, K.P.
    Schouten, T.
    Seyboth, P.
    Seyerlein, J.
    Nuclear instruments and methods in physics research, 1983, 225 (03): : 509 - 515
  • [9] Calorimeter studies with Geant4
    de Freitas, PM
    PHYSICS AND EXPERIMENTS WITH FUTURE LINEAR E(PLUS) E(MINUS) COLLIDERS, 2001, 578 : 658 - 661
  • [10] SSLG4: A novel scintillator simulation library for Geant4
    Kandemir, Mustafa
    Tiras, Emrah
    Kirezli, Burcu
    Koca, Ibrahim
    COMPUTER PHYSICS COMMUNICATIONS, 2025, 306