Operation of a Two-Phase Reverse Loop Thermosyphon

被引:3
|
作者
Tsai, Meng-Chang [1 ]
Kang, Shung-Wen [2 ]
Li, Heng-Yi [1 ]
Tsai, Wen-Fa [1 ]
机构
[1] Inst Nucl Energy Res, Taoyuan 325, Taiwan
[2] Tamkang Univ Tamsui, Dept Mech & Elect Mech Engn, Fujisawa, Kanagawa 251, Japan
来源
关键词
Reverse-loop; Thermosyphon; Heat Transfer Downward; Cyclic Operation;
D O I
10.6180/jase.2015.18.3.06
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A prototype two-phase reverse-loop thermosyphon (RLT) was fabricated to transport thermal energy downwards to a thermal storage tank. The effect the filling ratio exerted on the thermal performance of the RTL was investigated by conducting experiments that were performed by a range between 47% and 63%. The prototype device comprised an evaporator, a condenser, a reservoir (preheater), and pipes connecting each of the components. The heat transport height was 1500 mm from the evaporator to the bottom of the condenser. Methanol with a concentration of 95% was used as the working fluid. The temperature distribution, temperature difference between the evaporator and condenser, and thermal resistance of the thermosyphon were measured. In addition, a cyclic case, in which the power in coils was alternately switched on and off according to a square wave function was studied. The results indicated that the maximal thermal performance of the RLT occurred when the filling ratio was 60% and the input power was 660W.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [1] Instability of a two-phase loop thermosyphon
    Seok-Ho Rhi
    KSME International Journal, 2002, 16 : 1019 - 1028
  • [2] Instability of a two-phase loop thermosyphon
    Rhi, SH
    KSME INTERNATIONAL JOURNAL, 2002, 16 (07): : 1019 - 1028
  • [3] Two-phase thermosyphon loop laterally heated
    Bielinski, H
    Mikielewicz, J
    INZYNIERIA CHEMICZNA I PROCESOWA, 2005, 26 (02): : 339 - 351
  • [4] ANALYSIS OF TWO-PHASE THERMOSYPHON LOOP.
    Chen, K.S.
    Chang, Y.R.
    Chung-Kuo Chi Hsueh Kung Ch'eng Hsueh Pao/Journal of the Chinese Society of Mechanical Engineers, 1987, 8 (03): : 155 - 163
  • [5] NUMERICAL MODELLING OF THE OPERATION OF A TWO-PHASE THERMOSYPHON
    Kamburova, Veselka
    Ahmedov, Ahmed
    Iliev, Iliya K.
    Beloev, Ivan
    Pavlovic, Ivan R.
    THERMAL SCIENCE, 2018, 22 : S1311 - S1321
  • [6] CFD simulation on the operation characteristics of CO2 two-phase thermosyphon loop
    Tong, Zhen
    Wu, Hao
    Li, Xiaorui
    Han, Zekun
    APPLIED THERMAL ENGINEERING, 2023, 224
  • [7] Measurement of the performances of a transparent closed loop two-phase thermosyphon
    Agostini, B.
    Habert, M.
    ADVANCED COMPUTATIONAL METHODS AND EXPERIMENTS IN HEAT TRANSFER XI, 2010, 68 : 227 - 238
  • [8] Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
    Samba, Ahmadou
    Louahlia-Gualous, Hasna
    Le Masson, Stephane
    Noerterhaeuser, David
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1351 - 1360
  • [9] HEAT TRANSFER PERFORMANCE OF A PULSATED TWO-PHASE LOOP THERMOSYPHON
    Ashraful, Islam Md.
    Ashiqur, Rahman Md.
    Mohammed, Alam
    IMECE 2008: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, VOL 10, PTS A-C, 2009, : 1411 - 1419
  • [10] Two-Phase Closed-Loop Thermosyphon for Electronic Cooling
    Chang, C. -C.
    Kuo, S. -C.
    Ke, M. -T.
    Chen, S. -L.
    EXPERIMENTAL HEAT TRANSFER, 2010, 23 (02) : 144 - 156