MICELLAR CATALYSIS IN FLOW-INJECTION SYSTEMS - THE NITROSATION REACTION

被引:7
|
作者
JOHNSON, BF [1 ]
MALICK, RE [1 ]
GHEARING, B [1 ]
DORSEY, JG [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
FLOW INJECTION; MICELLE; CATALYSIS; NITROSATION;
D O I
10.1039/an9921701833
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of aqueous micellar carrier streams in flow injection is shown to catalyse on-line reactions and thereby improve the sensitivity relative to non-micellar systems. The effect of several different micellar systems on the nitrosation reaction of N,N-diethylaniline in acidic solution was investigated. The mechanism of the micellar enhancement is discussed and the sensitivities of the method in both aqueous and micellar media are compared. The presence of the cationic surfactant, cetyltrimethylammonium bromide, is shown to improve the sensitivity of the analysis. The effect of the micellar solution on the dispersion characteristics of the system was also studied. The greater viscosity of the micellar phase increases dispersion for non-reacting systems, but when monitoring a reaction product the increased reaction rate can counteract this and the micellar carrier can show less over-all dispersion than the aqueous carrier.
引用
收藏
页码:1833 / 1837
页数:5
相关论文
共 50 条
  • [1] GAS-DIFFUSION AND MICELLAR CATALYSIS IN THE FLOW-INJECTION DETERMINATION OF SULFITE
    PRIETO, AMG
    PAVON, JLP
    CORDERO, BM
    ANALYST, 1994, 119 (11) : 2447 - 2452
  • [2] Flow-Injection and Sequential-Injection Determinations of Paracetamol in Pharmaceutical Preparations Using Nitrosation Reaction
    Rodjana Burakham
    Supunnee Duangthong
    Lop Patimapornlert
    Narong Lenghor
    Suphaphorn Kasiwad
    Lalida Srivichai
    Somchai Lapanantnoppakhun
    Jaroon Jakmunee
    Kate Grudpan
    Analytical Sciences, 2004, 20 : 837 - 840
  • [3] Flow-injection and sequential-injection determinations of paracetamol in pharmaceutical preparations using nitrosation reaction
    Burakham, R
    Duangthong, S
    Patimapornlert, L
    Lenghor, N
    Kasiwad, S
    Srivichai, L
    Lapanantnoppakhun, S
    Jakmunee, J
    Grudpan, K
    ANALYTICAL SCIENCES, 2004, 20 (05) : 837 - 840
  • [4] MICELLAR SYSTEMS IN FLOW-INJECTION FOR THE SPECTROPHOTOMETRIC DETERMINATION OF NEODYMIUM IN GLASSES
    PAVON, JLP
    CORDERO, BM
    MENDEZ, JH
    MIRALLES, JC
    ANALYST, 1989, 114 (07) : 849 - 851
  • [5] MICELLAR-CATALYZED REACTIONS FOR FLOW-INJECTION SYSTEMS - DETERMINATION OF PYRIDOXAL
    TORRES, MAH
    KHALEDI, MG
    DORSEY, JG
    ANALYTICA CHIMICA ACTA, 1987, 201 : 67 - 76
  • [6] USE OF FLOW-INJECTION IN THE STUDY OF MICELLAR INTERACTIONS
    DELAGUARDIA, M
    PERISCARDELLS, E
    ANALYTICA CHIMICA ACTA, 1992, 256 (02) : 225 - 230
  • [7] MANUAL AND FLOW-INJECTION SPECTROPHOTOMETRIC ASSAY OF THIOLS, BASED ON THEIR S-NITROSATION
    VERMA, KK
    STEWART, KK
    JAIN, A
    GUPTA, D
    SANGHI, SK
    TALANTA, 1991, 38 (03) : 283 - 289
  • [8] MICELLAR-CATALYZED REACTIONS FOR FLOW-INJECTION SYSTEMS, DETERMINATION OF PYRIDOXAL-5-PHOSPHATE
    ALONSO, A
    ALMENDRAL, MJ
    MERINO, F
    PALERMO, SP
    ANALYST, 1995, 120 (09) : 2401 - 2405
  • [9] DISPERSION PHENOMENA IN FLOW-INJECTION SYSTEMS
    HULL, RD
    MALICK, RE
    DORSEY, JG
    ANALYTICA CHIMICA ACTA, 1992, 267 (01) : 1 - 24
  • [10] BEHAVIOR OF LIPOSOMES IN FLOW-INJECTION SYSTEMS
    LOCASCIOBROWN, L
    PLANT, AL
    DURST, RA
    ANALYTICAL CHEMISTRY, 1988, 60 (08) : 792 - 797