COMPARISON OF ENTRANCE AND EXIT DOSE MEASUREMENTS USING IONIZATION CHAMBERS AND SILICON DIODES

被引:64
|
作者
HEUKELOM, S
LANSON, JH
MIJNHEER, BJ
机构
[1] Radiotherapy Dept., Netherlands Cancer Inst., Amsterdam
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1991年 / 36卷 / 01期
关键词
D O I
10.1088/0031-9155/36/1/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A high precision patient dosimetry method has been developed, based on the use of p-type diodes. First, entrance as well as exit dose calibration factors have to be determined under reference irradiation conditions. Secondly, a set of correction factors must be added for situations deviating from the reference conditions, i.e. for different source-skin distances, phantom (patient) thicknesses, field sizes for insertion of a wedge into the photon beam. Finally some other detector characteristics such as the temperature dependence of the response have to be taken into account. For most irradiation conditions this procedure is sufficiently accurate to allow entrance as well as exit dose determinations with a diode to be in good agreement with dose values measured by an ionization chamber. The main factors effecting the value of the correction factors, the dependence of the diode sensitivity on the energy and the dose per pulse, have been investigated to explain some of the observed phenomena. Despite a strong energy dependence of the sensitivity, the correction factors are, for a particular type of diode, the same for 4 and 8 MV x-ray beams. The variation in the values for the correction factors with integrated dose received by the diode is small. These findings indicate that the correction factors, once available, can be applied under a number of circumstances. Due to the difference in behaviour of various diodes, even from the same batch, it is, however, necessary to determine the characteristics for each diode individually.
引用
收藏
页码:47 / 59
页数:13
相关论文
共 50 条
  • [1] Entrance and exit in vivo dose measurements; MOSFET, diodes and TLD
    Jornet, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S91 - S91
  • [2] TLD extrapolation measurements for entrance and exit dose in radiotherapy
    Kron, T
    Ostwald, PM
    Hamilton, CS
    Denham, JW
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 323 - 326
  • [3] Entrance and exit dose measurements with semiconductors and thermoluminescent dosemeters: A comparison of methods and in vivo results
    Loncol, T
    Greffe, JL
    Vynckier, S
    Scalliet, P
    RADIOTHERAPY AND ONCOLOGY, 1996, 41 (02) : 179 - 187
  • [4] ABSORBED DOSE MEASUREMENTS USING PARALLEL PLATE POLYSTYRENE IONIZATION CHAMBERS IN POLYSTYRENE PHANTOMS
    HOLT, JG
    BUFFA, A
    PERRY, DJ
    MA, IC
    MCDONALD, JC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (11/1): : 2031 - 2038
  • [5] Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements
    P. R. Satory
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 101 - 104
  • [6] Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements
    Satory, P. R.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 101 - 104
  • [7] COMPARISON OF TISSUE-EQUIVALENT IONIZATION CHAMBER AND SILICON DIODES FOR MEASURING FAST NEUTRON DOSE
    BATCHELOR, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 451 - +
  • [8] MEASUREMENT OF DOSE EQUIVALENT USING PAIRED IONIZATION CHAMBERS
    GOODMAN, LJ
    ROSSI, HH
    HEALTH PHYSICS, 1968, 14 (02): : 168 - +
  • [9] Uncertainty evaluation in activity measurements using ionization chambers
    Amiot, M. N.
    Chiste, V.
    Fitzgerald, R.
    Juget, F.
    Michotte, C.
    Pearce, A.
    Ratel, G.
    Zimmerman, B. E.
    METROLOGIA, 2015, 52 (03) : S108 - S122
  • [10] Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector
    Annamalai, Gopiraj
    Velayudham, Ramasubramanian
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2009, 14 (05) : 176 - 183