A comparison of 0.1% ropivacaine and 0.1% bupivacaine with patient-controlled epidural analgesia for labor: a double blind study

被引:0
|
作者
Anand, Lakesh K. [1 ]
Sarna, Rashi [2 ]
Mitra, Sukanya
机构
[1] Govt Med Coll & Hosp, Dept Anesthesia & Intens Care, Sect 32, Chandigarh 160030, India
[2] Adesh Med Coll & Hosp, Dept Anesthesia, Ambala Cant, Haryana, India
关键词
Labor analgesia; Bupivacaine; Ropivacaine; Fentanyl; Patient-controlled epidural analgesia;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Ropivacaine has been claimed to be superior for epidural labor analgesia, with less motor blockade and toxicity as compared to bupivacaine, and it has largely replaced the later drug for this purpose. The objective of this study was to compare and evaluate the analgesic efficacy of ropivacaine 0.1% and bupivacaine 0.1% with 2 mu g/ml fentanyl for painless labor using patient-controlled epidural analgesia (PCEA). Methodology: This prospective, randomized and double blind study was undertaken in a tertiary care hospital. Fifty parturients of ASA grade I and II, were randomly allocated into two groups of 25 each, to receive either 10 ml of 0.1% bupivacaine or 0.1% ropivacaine with fentanyl 2 mu g/ml in Group B and Group R respectively as initial bolus dose. Same dose regimen was used as continuous background infusion and PCEA boluses of 10 ml according to the group allocation. Onset and quality of analgesia, motor weakness, total drug consumption, and fetomaternal outcome in both groups were compared. Results: Effective labor analgesia (VAS < 30) with onset time of 9.42 +/- 1.16 and 9.14 +/- 1.46 min in Group B and Group R respectively were comparable in both the groups (p > 0.05). All the patients were pain free within 15 min after initiation of epidural analgesia. Sensory and motor block characteristics in both the groups were comparable. No patient had motor blockade till two hours after initiation of epidural analgesia. Motor block increased as the duration of labor increased. Overall, drug consumption was 85.04 +/- 21.02 ml in Group R and 81.56 +/- 22.81 ml in Group B with fentanyl during labor (p >= 0.05). There were no significant changes in hemodynamic parameters, duration of labor or maternal satisfaction. No adverse effects related to neonatal or maternal outcomes were noted in both groups. Conclusion: We conclude that 0.1% ropivacaine or 0.1% bupivacaine with fentanyl 2 mu g/ml using PCEA were equally effective for labor analgesia. There were no statistically significant differences in the quantity of drug used, motor weakness, labor duration, or fetomaternal outcome.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 50 条
  • [1] Ropivacaine, 0.1% plus sufentanil, 0.5 μg/ml, versus bupivacaine, 0.1% plus sufentanil, 0.5 μg/ml, using patient-controlled epidural analgesia for labor -: A double-blind comparison
    Fischer, C
    Blanié, P
    Jaouën, E
    Vayssière, C
    Kaloul, I
    Coltat, JC
    ANESTHESIOLOGY, 2000, 92 (06) : 1588 - 1593
  • [2] Epidural infusions for labor analgesia: A comparison of 0.2% ropivacaine, 0.1% ropivacaine, and 0.1% ropivacaine with fentanyl
    Lee, BB
    Kee, WDN
    Lau, WM
    Wong, ASY
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (01) : 31 - 36
  • [3] A comparison of 0.0625% bupivacaine with fentanyl and 0.1% ropivacaine with fentanyl for continuous epidural labor analgesia
    Fernandez-Guisasola, J
    Serrano, ML
    Cobo, B
    Muñoz, L
    Plaza, A
    Trigo, C
    del Valle, SG
    ANESTHESIA AND ANALGESIA, 2001, 92 (05): : 1261 - 1265
  • [4] A comparison of 0.1% and 0.2% ropivacaine and bupivacaine combined with morphine for postoperative patient-controlled epidural analgesia after major abdominal surgery
    Senard, M
    Joris, JL
    Ledoux, D
    Toussaint, PJ
    Lahaye-Goffart, B
    Lamy, ML
    ANESTHESIA AND ANALGESIA, 2002, 95 (02): : 444 - 449
  • [5] Comparison of patient-controlled epidural bolus administration of 0.1% ropivacaine and 0.1% levobupivacaine, both with 0.0002% fentanyl, for analgesia during labour
    Purdie, NL
    McGrady, EM
    ANAESTHESIA, 2004, 59 (02) : 133 - 137
  • [6] Comparison between postoperative patient-controlled epidural analgesia of buprenorphine plus droperidol with 0.1% bupivacaine and without 0.1% bupivacaine for gynecological surgery.
    Inoue, S
    Togashi, H
    Hirabayashi, Y
    Soutome, K
    Akazawa, S
    Shimizu, R
    ANESTHESIOLOGY, 1998, 89 (3A) : U922 - U922
  • [7] A comparison of ropivacaine with fentanyl to bupivacaine with fentanyl for postoperative patient-controlled epidural analgesia
    Hodgson, PS
    Liu, SS
    ANESTHESIA AND ANALGESIA, 2001, 92 (04): : 1024 - 1028
  • [8] Patient-controlled epidural analgesia with 0.0625% ropivacaine versus bupivacaine with fentanyl during labor
    Smiley, RM
    Kim-Lo, SH
    Goodman, SR
    Jackson, MA
    Landau, R
    ANESTHESIOLOGY, 2000, 93 (3A) : U213 - U213
  • [9] Improving ropivacaine 0.1% epidural labor analgesia
    Bonnemere, V
    Brichant, JF
    Dewandre, PY
    Hans, P
    Lamy, M
    ANESTHESIOLOGY, 2000, 93 (3A) : U212 - U212
  • [10] Comparison of bupivacaine, ropivacaine and levobupivacaine with sufentanil for patient-controlled epidural analgesia during labor: a randomized clinical trial
    Wang Li-zhong
    Chang Xiang-yang
    Liu Xia
    Hu Xiao-xia
    Tang Bei-lei
    CHINESE MEDICAL JOURNAL, 2010, 123 (02) : 178 - 183