Effects of instrument flow rate, sensitivity, and background noise on cleanroom particle count statistics

被引:0
|
作者
Knollenberg, RG
Haley, BT
Steidtmann, DE
机构
来源
关键词
cleanrooms; particle size; distribution; condensation nucleus counters; laser particle counters; filtration;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Detailed particle microcontamination measurements were made in Class 100 and Class IO [unidirectional flow, or vertical laminar flow (VLF)] environments used as final assembly and electro-optical assembly areas, respectively, at Particle Measuring Systems, Inc. (PMS), Two groups of measuring instruments monitoring the two areas included four laser particle counters (LPCs) and three condensation nucleus counters (CNCs). The utility of both types of measurements in these environments is discussed relative to sensitivity, flow rate, and background noise. These data indicate that the statistical advantage of CNCs over 1 cu ft/min LPCs can only be achieved at flow rates > 0.50 cu ft/min. The most prevalent range of particle sizes is limited to those near the most penetrating particle size, The higher count rare of lower flow rate CNC and LPC instruments was also found to be a factor in quantifying episodic events and transient populations. Outside ambient air was shown to be the major contributor to in-room particle counts under the conditions studied here.
引用
收藏
页码:18 / 29
页数:14
相关论文
共 50 条
  • [1] STATISTICS OF COHERENT SIGNAL COUNT AGAINST A NOISE BACKGROUND
    LASKIN, NV
    MAZMANISHVILI, AS
    UKRAINSKII FIZICHESKII ZHURNAL, 1983, 28 (12): : 1871 - 1873
  • [2] Particle dispersion in a cleanroom - Effects of pressurization, door opening and traffic flow
    Bhattacharya, Arup
    Metcalf, Andrew R.
    Nafchi, Ali Mohammadi
    Mousavi, Ehsan S.
    JOURNAL OF PLANNING LITERATURE, 2022, 37 (01) : 201 - 201
  • [3] Particle dispersion in a cleanroom - effects of pressurization, door opening and traffic flow
    Bhattacharya, Arup
    Metcalf, Andrew R.
    Nafchi, Ali Mohammadi
    Mousavi, Ehsan S.
    BUILDING RESEARCH AND INFORMATION, 2021, 49 (03): : 294 - 307
  • [4] Evaluation of the effects of flow rate reduction on the environmental parameters of an operational cleanroom
    Jue, M
    Wang, RD
    Huang, T
    Fillipovic, A
    Hundt, A
    Cooper, DW
    2000 PROCEEDINGS: INSTITUTE OF ENVIRONMENTAL SCIENCES AND TECHNOLOGY, 2000, : 95 - 100
  • [5] Evaluating the effects of flow rate reduction on the environmental parameters of an operational cleanroom
    Jue, M
    Wang, RD
    Huang, T
    Fillipovic, A
    Hundt, A
    Cooper, DW
    JOURNAL OF THE IEST, 2000, 43 (04): : 38 - 43
  • [6] Effects of noise sensitivity and listening effort on perceptual ratings of background noise
    von Berg, Markus
    Himmelein, Hendrik
    Steffens, Jochen
    JASA EXPRESS LETTERS, 2024, 4 (08):
  • [7] Effects of the particle size and flow rate on the rate of adsorption
    Fan, Shanying
    Zhou, Peiqing
    Xu, Rongnan
    Lizi Jiaohuan Yu Xifu/Ion Exchange and Adsorption, 1996, 12 (06): : 537 - 541
  • [8] Modulation of Firing Rate by Background Synaptic Noise Statistics in Rat Visual Cortical Neurons
    Sceniak, Michael P.
    Sabo, Shasta L.
    JOURNAL OF NEUROPHYSIOLOGY, 2010, 104 (05) : 2792 - 2805
  • [9] Influence of background noise on the performance in the odor sensitivity task: effects of noise type and extraversion
    Han-Seok Seo
    Antje Hähner
    Volker Gudziol
    Mandy Scheibe
    Thomas Hummel
    Experimental Brain Research, 2012, 222 : 89 - 97
  • [10] Influence of background noise on the performance in the odor sensitivity task: effects of noise type and extraversion
    Seo, Han-Seok
    Haehner, Antje
    Gudziol, Volker
    Scheibe, Mandy
    Hummel, Thomas
    EXPERIMENTAL BRAIN RESEARCH, 2012, 222 (1-2) : 89 - 97