PRESERVATION OF DISTAL CORONARY PERFUSION DURING PROLONGED BALLOON INFLATION WITH AN AUTOPERFUSION ANGIOPLASTY CATHETER

被引:52
|
作者
TURI, ZG [1 ]
CAMPBELL, CA [1 ]
GOTTIMUKKALA, MV [1 ]
KLONER, RA [1 ]
机构
[1] WAYNE STATE UNIV,SCH MED,DEPT MED,DETROIT,MI 48201
关键词
D O I
10.1161/01.CIR.75.6.1273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1273 / 1280
页数:8
相关论文
共 50 条
  • [1] THE AUTOPERFUSION BALLOON ANGIOPLASTY CATHETER PREVENTS ISCHEMIA DURING PROLONGED BALLOON INFLATION
    TURI, Z
    CAMPBELL, CA
    KLONER, RA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A106 - A106
  • [2] PROTECTION AGAINST ISCHEMIA DURING PROLONGED BALLOON INFLATION BY DISTAL CORONARY PERFUSION WITH USE OF AN AUTOPERFUSION CATHETER OR FLUOSOL
    ROBALINO, BD
    MARWICK, T
    LAFONT, A
    VASKA, K
    WHITLOW, PL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (06) : 1378 - 1384
  • [3] DISTAL PERFUSION DURING PROLONGED BALLOON INFLATION IN CORONARY ANGIOPLASTY (PTCA)
    ANDERSON, HV
    TEAGUE, DL
    CIRCULATION, 1984, 70 (04) : 37 - 37
  • [4] THE AUTOPERFUSION BALLOON ANGIOPLASTY CATHETER LIMITS MYOCARDIAL ISCHEMIA AND NECROSIS DURING PROLONGED BALLOON INFLATION
    CAMPBELL, CA
    REZKALLA, S
    KLONER, RA
    TURI, ZG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 1045 - 1050
  • [5] LEFT MAIN CORONARY ANGIOPLASTY - PRESERVATION OF DISTAL BLOOD-FLOW USING A NEW AUTOPERFUSION BALLOON CATHETER
    TURI, ZG
    REZKALLA, S
    CAMPBELL, CA
    KLONER, RA
    CIRCULATION, 1987, 76 (04) : 466 - 466
  • [6] MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AN AUTOPERFUSION BALLOON CATHETER IN HUMANS
    QUIGLEY, PJ
    HINOHARA, T
    PHILLIPS, HR
    PETER, RH
    BEHAR, VS
    KONG, YH
    SIMONTON, CA
    PEREZ, JA
    STACK, RS
    CIRCULATION, 1988, 78 (05) : 1128 - 1134
  • [7] Coronary artery angioplasty with a helical autoperfusion balloon catheter
    Gurbel, PA
    Anderson, RD
    Peels, HO
    vanBoven, AJ
    denHeijer, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 40 (02): : 179 - 185
  • [8] PRESERVATION OF REGIONAL MYOCARDIAL-FUNCTION DURING CORONARY ANGIOPLASTY WITH AN AUTOPERFUSION BALLOON CATHETER - A CASE-REPORT
    SIMONTON, CA
    KOWALCHUK, GJ
    AUSTIN, WK
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 22 (01): : 28 - 34
  • [9] FRACTURE OF A PERFUSION BALLOON CATHETER DURING CORONARY ANGIOPLASTY
    KUAN, PL
    KO, YL
    TSAI, CH
    LIN, JL
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (01): : 33 - 35
  • [10] PROLONGED DILATION WITH AN AUTOPERFUSION BALLOON CATHETER FOR REFRACTORY ACUTE OCCLUSION RELATED TO PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    VANDERLINDEN, LP
    BAKX, ALM
    SEDNEY, MI
    BUIS, B
    BRUSCHKE, AVG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) : 1016 - 1023