APPLICATION OF CRYO-SAPPHIRE KNIFE IN RAPID FROZEN ULTRATHIN SECTIONING FOR ELECTRON-MICROSCOPY

被引:0
|
作者
SUZUKI, K
AIHARA, K
HANAICHI, T
TAKAGI, I
SATO, T
机构
[1] SCH HYG,DEPT ANAT,AICHI,JAPAN
[2] NAGOYA UNIV,SCH MED,CENT LAB ELECTRON MICROSCOPY,NAGOYA,AICHI 464,JAPAN
[3] NIPPON MED COLL,WHO COLLABORATING CTR RES & TRAINING DIAGNOST ELECTRON MICROSCOPY,TOKYO 113,JAPAN
[4] FUJITA GAKUEN UNIV,CENT LAB ELECTRON MICROSCOPY,TOYOAKE,AICHI 47011,JAPAN
关键词
SAPPHIRE KNIFE; CRYO ULTRA-SECTIONING;
D O I
暂无
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Conventional sectioning of frozen and fixed tissues is usually performed using the glass knife. Although the glass knife is economical, it has several disadvantages. In this study, the Authors have examined the sectioning quality of the sapphire knife in frozen tissues as an alternative to the glass knife. It was concluded that the sapphire knife has better quality and durability than the conventional glass knife in cutting frozen tissues.
引用
收藏
页码:629 / 634
页数:6
相关论文
共 50 条
  • [1] 1-A-2, IMPROVEMENT OF SAPPHIRE KNIFE FOR CRYO SECTIONING FOR BIOLOGICAL ELECTRON-MICROSCOPY
    SUZUKI, K
    AIHARA, K
    HANAICHI, T
    TAKAGI, I
    SATO, T
    JOURNAL OF ELECTRON MICROSCOPY, 1989, 38 (04): : 252 - 252
  • [2] MEGAVOLT AND CRYO ELECTRON-MICROSCOPY OF DIAMOND KNIFE EDGES
    FERNANDEZMORAN, H
    ULTRAMICROSCOPY, 1986, 20 (03) : 317 - 328
  • [3] USEFULNESS OF A SAPPHIRE KNIFE IN ULTRATHIN SECTIONING OF BIOLOGICAL SPECIMENS
    YAMAMOTO, I
    MARUYAMA, H
    JOURNAL OF ELECTRON MICROSCOPY, 1985, 34 (04): : 442 - 447
  • [4] USEFULNESS OF SAPPHIRE KNIFE IN ULTRATHIN SECTIONING OF BIOLOGICAL SPECIMENS
    YAMAMOTO, I
    MARUYAMA, H
    YAMAMOTO, T
    JOURNAL OF ELECTRON MICROSCOPY, 1984, 33 (03): : 268 - 268
  • [5] FREEZING, SECTIONING AND OBSERVATION ARTIFACTS OF FROZEN HYDRATED SECTIONS FOR ELECTRON-MICROSCOPY
    CHANG, JJ
    MCDOWALL, AW
    LEPAULT, J
    FREEMAN, R
    WALTER, CA
    DUBOCHET, J
    JOURNAL OF MICROSCOPY, 1983, 132 (OCT) : 109 - 123
  • [6] A METHOD FOR SECTIONING AND HANDLING FROZEN-SECTIONS FOR SCANNING ELECTRON-MICROSCOPY
    MOWRY, TM
    WHALON, ME
    KLOMPARENS, K
    JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1986, 3 (02): : 211 - 215
  • [7] (CRYO-ULTRAMICROTOMY AS A RAPID METHOD FOR ELECTRON-MICROSCOPY)
    MORGENSTERN, E
    NEUMANN, K
    WERNER, G
    MIKROSKOPIE, 1973, 29 (5-6) : 163 - 178
  • [8] CRYO ELECTRON-MICROSCOPY
    ZEITLER, E
    ULTRAMICROSCOPY, 1982, 10 (1-2) : 1 - 5
  • [9] CRYO ELECTRON-MICROSCOPY
    ZEITLER, E
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1988, (93): : 27 - 32
  • [10] CRYO ELECTRON-MICROSCOPY
    ZEITLER, E
    EUREM 88, VOLS 1-3: TUTORIALS, INSTRUMENTATION AND TECHNIQUES / PHYSICS AND MATERIALS / BIOLOGY, 1988, 93 : 27 - 32