THE ACCURACY OF CT ANGIOGRAPHY FOR THE DEMONSTRATION OF RENAL-ARTERY STENOSIS

被引:42
|
作者
GALANSKI, M [1 ]
PROKOP, M [1 ]
CHAVAN, A [1 ]
SCHAEFER, C [1 ]
JANDELEIT, K [1 ]
OLBRICHT, C [1 ]
机构
[1] HANNOVER MED SCH,NEPHROL ABT,D-30625 HANNOVER,GERMANY
关键词
CT ANGIOGRAPHY; SPIRAL CT; RENAL ARTERY STENOSIS; RENOVASCULAR HYPERTENSION;
D O I
10.1055/s-2008-1032579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral CT in the form of CT angiography (CTA) provides a new method for the investigation of the large vessels. 52 patients with suspected renovascular hypertension were examined by CTA and arterial DSA. The computer tomographic and angiographic findings in 124 renal arteries were compared. Sensitivity of CTA for demonstrating renal artery stenosis was 95%, and for relevant stenoses it actually reached 100%. Specificity was 92%. Positive/negative prediction value was 85% and 100%. CTA proved outstandingly good for demonstrating or excluding renal artery stenosis and was superior to other imaging methods in several respects. CTA requires high contrast values, optimal timing and careful evaluation. Amongst various forms of image reconstruction, interactive viewing of the primary axial images and multiplanar reconstruction in a cine mode are essential and MIP projections are valuable.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [1] SPIRAL CT ANGIOGRAPHY OF RENAL-ARTERY STENOSIS - COMPARISON WITH ARTERIOGRAPHY
    RUBIN, GD
    DAKE, MD
    NAPEL, SA
    JEFFREY, RB
    RADIOLOGY, 1992, 185 : 163 - 163
  • [2] CT-DETECTED RENAL ARTERIAL CALCIFICATION - CORRELATION WITH RENAL-ARTERY STENOSIS ON ANGIOGRAPHY
    SIEGEL, CL
    ELLIS, JH
    KOROBKIN, M
    DUNNICK, NR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) : 867 - 872
  • [3] NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS (RAS) BY SPIRAL CT ANGIOGRAPHY (CTA)
    OLBRICHT, CJ
    PAUL, K
    PROKOP, M
    CHAVAN, A
    SCHAEFERPROKOP, CM
    JANDELEIT, K
    KOCH, KM
    GALANSKI, M
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 565 - 565
  • [4] The interobserver agreement and diagnostic accuracy of renal CT angiography and MR angiography for the diagnosis of renal-artery stenosis. Results of the renal artery diagnostic imaging study in hypertension (RADISH)
    Vasbinder, GBC
    Nelemans, PJ
    Kroon, AA
    Postma, CT
    Beutler, JJ
    Thien, T
    de Leeuw, PW
    van Engelshoven, JMA
    JOURNAL OF HYPERTENSION, 2003, 21 : S16 - S16
  • [5] MAGNETIC-RESONANCE ANGIOGRAPHY OF RENAL-ARTERY STENOSIS
    GEDROYC, WMW
    NEERHUT, P
    NEGUS, R
    PALMER, A
    ALKUTOUBI, A
    TAUBE, D
    HULME, B
    CLINICAL RADIOLOGY, 1995, 50 (07) : 436 - 439
  • [6] MAGNETIC-RESONANCE ANGIOGRAPHY OF RENAL-ARTERY STENOSIS
    GRIST, TM
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) : 700 - 712
  • [7] RENAL-ARTERY STENOSIS
    MAIN, J
    WARD, M
    LOOSE, H
    WILKINSON, R
    BRITISH MEDICAL JOURNAL, 1991, 302 (6768): : 115 - 115
  • [8] EVALUATION OF RENAL-ARTERY STENOSIS BY MAGNETIC-RESONANCE ANGIOGRAPHY
    HERTZ, SM
    HOLLAND, GA
    BAUM, RA
    HASKAL, ZJ
    CARPENTER, JP
    AMERICAN JOURNAL OF SURGERY, 1994, 168 (02): : 140 - 143
  • [9] RENAL-ARTERY STENOSIS
    SCHACHT, RA
    CONWAY, J
    ZWEIFLER, AJ
    GOLDBLATT, H
    NEW ENGLAND JOURNAL OF MEDICINE, 1964, 271 (01): : 55 - &
  • [10] UNILATERAL RENAL-ARTERY STENOSIS AND HYPERTENSION .1. ANGIOGRAPHY
    ANDERSSON, I