Transient Heat Transfer in an Out-of-Pile SCWR Fuel Assembly Test at Near-Critical Pressure

被引:3
|
作者
Schulenberg, Thomas [1 ]
Li, Hongbo [2 ]
机构
[1] Karlsruhe Inst Technol, D-76344 Eggenstein Leopoldshafen, Germany
[2] China Nucl Power Technol Res Inst Co Ltd, Shenzhen 518026, Peoples R China
关键词
D O I
10.1115/1.4038061
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
While supercritical water is a perfect coolant with excellent heat transfer, a temporary decrease of the system pressure to subcritical conditions, either during intended transients or by accident, can easily cause a boiling crisis with significantly higher cladding temperatures of the fuel assemblies. These conditions have been tested in an out-of-pile experiment with a bundle of four heated rods in the supercritical water multipurpose loop (SWAMUP) facility coconstructed by CGNPC and SJTU in China. Some of the transient tests have been simulated at KIT with a one-dimensional (1D) MATLAB code, assuming quasi-steady-state flow conditions, but time dependent temperatures in the fuel rods. Heat transfer at supercritical and at near-critical conditions was modeled with a recent look-up table of Zahlan (2015, "Derivation of a Look-Up Table for Trans-Critical Heat Transfer in Water Cooled Tubes," Ph.D. dissertation, University of Ottawa, Ottawa, ON, Canada.), and subcritical film boiling was modeled with the look-up table of Groeneveld et al. (2003, "A Look-Up Table for Fully Developed Film Boiling Heat Transfer," Nucl. Eng. Des., 225(1), pp. 83-97.). Moreover, a conduction controlled rewetting process was included in the analyses, which is based on an analytical solution of Schulenberg and Raque (2014, "Transient Heat Transfer During Depressurization From Supercritical Pressure," Int. J. Heat Mass Transfer, 79(12), pp. 233-240.). The method could well reproduce the boiling crisis during depressurization from supercritical to subcritical pressure, including rewetting of the hot zone within some minutes, but the peak temperature was somewhat under-predicted. Tests with a lower heat flux, which did not cause such phenomena, could be predicted as well. In another test with increasing pressure, however, a boiling crisis was also observed at a heat flux, which was significantly lower than the critical heat flux (CHF) predicted by the CHF look-up table of Groeneveld et al. (2007, "The 2006 CHF Look-Up Table," Nucl. Eng. Des., 237(15-17), pp. 1909-1922.). The paper is summarizing the physical models and the numerical approach. Comparison with experimental data is used to discuss the applicability of the method for the design of supercritical water-cooled reactors (SCWR).
引用
收藏
页数:7
相关论文
共 50 条
  • [1] OUT-OF-PILE HEAT TRANSFER TEST DEVICE FOR LOW PRESSURE IRRADIATION CAPSULE
    Ma Yongzhe
    Zhang Peisheng
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 1, 2014,
  • [2] HEAT TRANSFER IN A HORIZONTAL COILED PIPE IN A TRANSIENT REGIME AND AT A NEAR-CRITICAL PRESSURE OF A FLUID
    Kelbaliev, R. F.
    Aliev, R. Yu.
    Ismailov, M. B.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2008, 81 (05) : 930 - 934
  • [3] Out-of-pile hydraulic stability test of China advanced research reactor standard fuel assembly
    Zhang, Ying-Chao
    Liu, Yan
    Chen, Li-Xia
    Kang, Ya-Lun
    Wang, Hui
    Ding, Zhen-Xin
    Wang, Ling
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2009, 43 (07): : 622 - 625
  • [4] MEASUREMENT OF TEMPERATURE NOISE IN AN OUT-OF-PILE HEAT TRANSFER LOOP
    NISHIHARA, H
    OHTSUBO, A
    JOURNAL OF NUCLEAR ENERGY, 1969, 23 (02): : 99 - +
  • [5] Studies on the restructuring of fast breeder test reactor fuel by out-of-pile simulation
    Antony, MP
    Daniel, J
    Mathews, CK
    NUCLEAR TECHNOLOGY, 1997, 117 (03) : 299 - 305
  • [6] Improved correlations of the fuel/cladding liquid penetration rate with the out-of-pile transient database
    Shu, Shipeng
    Miao, Yinbin
    Oaks, Aaron
    Mo, Kun
    Tomchik, Carolyn
    Yacout, Abdellatif M.
    NUCLEAR ENGINEERING AND DESIGN, 2024, 417
  • [7] Analysis of Heat Transfer Characteristics of Canadian SCWR Fuel Assembly Concept
    Nava Dominguez, A.
    Rao, Y. F.
    Beuthe, T.
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2020, 6 (03):
  • [8] HEAT-TRANSFER CHARACTERISTICS IN RIFLED TUBES AT THE NEAR-CRITICAL PRESSURE REGION
    IWABUCHI, M
    TATEIWA, M
    HANEDA, H
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1983, 26 (214): : 678 - 678
  • [9] Developing Separate Effects Transient Test Experiments Using an Out-of-Pile Flowing Water Loop
    Marcum, Wade
    LaBrier, Daniel
    Brown, Emory
    Yan, Yikuan
    Woolstenhulme, Nicolas
    NUCLEAR TECHNOLOGY, 2020, 206 (06) : 895 - 910
  • [10] HEAT-TRANSFER TO NEAR-CRITICAL HELIUM IN HORIZONTAL CHANNELS
    DOLGOY, ML
    KIRICHENKO, YA
    SKLOVSKY, YB
    TROYANOV, AM
    CHERNYAKOV, PS
    CRYOGENICS, 1983, 23 (03) : 125 - 126