COMPARISON BETWEEN PEAK EXPIRATORY FLOW-RATES (PEFR) AND FEV1 IN THE MONITORING OF ASTHMATIC SUBJECTS AT AN OUTPATIENT-CLINIC

被引:53
|
作者
GAUTRIN, D
DAQUINO, LC
GAGNON, G
MALO, JL
CARTIER, A
机构
[1] Department of Chest Medicine, Sacre-Coeur Hospital, Montreal, Que.
关键词
AIRWAY CALIBER; AIRWAY OBSTRUCTION; ASTHMA; FEV(1); MAXIMAL EXPIRATORY NOW RATES; OBSTRUCTIVE LUNG DISEASES; PEFR;
D O I
10.1378/chest.106.5.1419
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Peak expiratory flow rate (PEFR) monitoring is often used alone in evaluating bronchial caliber and the response to a bronchodilator in the assessment of asthmatic subjects. A 15% change in airway caliber has been proposed as the criteria for modifying treatment. Our aim was to determine if changes in PEFR from one visit to the next can adequately evaluate changes in airway caliber as assessed by FEV(1), which is considered the gold standard, and to identify the characteristics of subjects whose evaluations were inadequate. This was a retrospective study of 197 asthmatic subjects seen regularly at an outpatient clinic for whom FEV(1) and PEFR assessments, prebronchodilator and postbronchodilator, were available for two visits. There was a high correlation between PEFR and FEV(1) (in absolute value or percent predicted) (r=0.83 and r=0.75). However, 24 of 56 (43%) of those who had a change in FEV(1) of 15% or more between two visits (mean change [%]+/-SD, range [best-lowest/best]=20.9+/-5.1%, 15 to 36%) showed changes in PEFR of less than 15% (6.7+/-6.5%, 8.0 to 13.9%). On the other hand, 14 of 42 (33%) subjects with changes in FEV(1) of less than 15% (9.8+/-3.2%, 1.1 to 13.8%) had changes in PEFR of 15% or more (22.2+/-10.9%, 16 to 35%). This discrepancy was not related to differences in baseline FEV(1), control status, or the relationship between changes in FEV(1) and PEFR in response to a bronchodilator. In conclusion, assessment of airway caliber through PEFR monitoring may not be valid in some asthmatic subjects and can often lead to underestimation or overestimation of changes in FEV(1). None of the explanations considered made it possible to identify these subjects.
引用
收藏
页码:1419 / 1426
页数:8
相关论文
共 50 条
  • [1] RELIABILITY OF PEAK EXPIRATORY FLOW-RATES (PEFR) COMPARED TO FEV(1) IN THE ASSESSMENT OF OUTPATIENT ASTHMATICS
    GAUTRIN, D
    CARTIER, A
    DAGUINO, LC
    GAGNON, G
    MALO, JL
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A995 - A995
  • [2] COMPARISON OF CIRCADIAN VARIATIONS USING FEV(1) AND PEAK EXPIRATORY FLOW-RATES AMONG NORMAL AND ASTHMATIC SUBJECTS
    TROYANOV, S
    GHEZZO, H
    CARTIER, A
    MALO, JL
    THORAX, 1994, 49 (08) : 775 - 780
  • [3] COMPLIANCE WITH SERIAL MONITORING OF PEAK EXPIRATORY FLOW-RATES (PEFR) IN ASTHMA
    LARCHEVQUE, J
    TRUDEAU, C
    CARTIER, A
    MALO, JL
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1995, 95 (01) : 223 - 223
  • [4] Comparison of serial monitoring of peak expiratory flow and FEV1 in the diagnosis of occupational asthma
    Leroyer, C
    Perfetti, L
    Trudeau, C
    L'Archevêque, J
    Chan-Yeung, M
    Malo, JL
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (03) : 827 - 832
  • [5] MONITORING OF PEAK EXPIRATORY FLOW-RATES IN SUBJECTS WITH MILD AIRWAY HYPEREXCITABILITY
    BAHOUS, J
    CARTIER, A
    MALO, JL
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1985, 21 (01): : 25 - 30
  • [6] AN ASSESSMENT OF PEAK EXPIRATORY FLOW AS A SURROGATE MEASUREMENT OF FEV1 IN STABLE ASTHMATIC-CHILDREN
    MELTZER, AA
    SMOLENSKY, MH
    DALONZO, GE
    HARRIST, RB
    SCOTT, PH
    CHEST, 1989, 96 (02) : 329 - 333
  • [7] HOME MONITORING OF ASTHMA WITH PEAK EXPIRATORY FLOW-RATES
    TWAROG, FJ
    ANNALS OF ALLERGY, 1991, 67 (05): : 457 - 460
  • [8] Peak expiratory flow as an endpoint for clinical trials in asthma: a comparison with FEV1
    David M. G. Halpin
    Eli O. Meltzer
    Wendelgard Pisternick-Ruf
    Petra Moroni-Zentgraf
    Michael Engel
    Liliana Zaremba-Pechmann
    Thomas Casale
    J. Mark FitzGerald
    Respiratory Research, 20
  • [9] Peak expiratory flow as an endpoint for clinical trials in asthma: a comparison with FEV1
    Halpin, David M. G.
    Meltzer, Eli O.
    Pisternick-Ruf, Wendelgard
    Moroni-Zentgraf, Petra
    Engel, Michael
    Zaremba-Pechmann, Liliana
    Casale, Thomas
    FitzGerald, J. Mark
    RESPIRATORY RESEARCH, 2019, 20 (1): : 159
  • [10] EVALUATION OF THE FERRARIS POCKET PEAK FLOW METER FOR THE MEASUREMENT OF PEAK EXPIRATORY FLOW-RATE (PEFR), AND FORCED EXPIRATORY VOLUME IN THE 1ST SECOND (FEV1)
    NOLAN, KM
    DORNELLY, SM
    HUGHES, DT
    STRUNIN, L
    RESPIRATORY MEDICINE, 1992, 86 (06) : 525 - 526