DETERMINATION OF U-85575 IN RAT SERUM BY SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:0
|
作者
WILLIAMS, MG [1 ]
ZHONG, WZ [1 ]
机构
[1] UPJOHN LABS,DRUG METAB RES,KALAMAZOO,MI 49001
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 03期
关键词
D O I
10.1080/10826079308019561
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid phase extraction and liquid chromatographic methods are described for the isolation and quantitataon of U-85575 from rat serum. The assay utilizes a simple extraction of U-85575 from serum with phenyl solid phase columns. The extracts were chromatographed on a CN reverse-phase column using a mobile phase of acetonitrile-water (32:68, v/v) containing 0.2% triethylamine (pH 6.5 +/- 0.05). The method has a limit of quantitation of 50 ng/ml of U-85575 in serum and is linear in the range of 0.05 to 20 mug/ml. The precision and accuracy of this method was proved to be <10% at the three concentrations evaluated. The method was demonstrated to be suitable to determine U-85575 concentrations in rat serum samples collected from a preliminary 15-day toxicity study.
引用
收藏
页码:743 / 753
页数:11
相关论文
共 50 条