HIGH-SENSITIVITY, HIGH-RESOLUTION MEASUREMENTS OF RADIATED POWER ON TEXT-U

被引:9
|
作者
WEN, YZ [1 ]
BRAVENEC, RV [1 ]
机构
[1] UNIV TEXAS,FUS RES CTR,AUSTIN,TX 78712
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 01期
关键词
D O I
10.1063/1.1146348
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Investigations of a possible radiation drive of edge turbulence in tokamaks require sensitive radiated power measurements having high temporal and spatial resolution. A commercially available 16-element X-UV-enhanced photodiode array having essentially 100% quantum efficiency from ∼25 to ≥6 keV is used. The frequency response is presently limited by the amplifiers to ∼50 kHz, although the ultimate response is expected to be much higher (>200 kHz). Each element's view is ∼0.4 cm wide along the major radius at the plasma midplane while the view of the entire array is ∼6.3 cm wide and is scannable over the entire plasma cross section. The details of the system as well as observations of fine spatial structures and fluctuations undetectable by conventional bolometers are presented. © 1995 American Institute of Physics.
引用
收藏
页码:549 / 551
页数:3
相关论文
共 50 条
  • [1] HIGH-RESOLUTION, HIGH-SENSITIVITY AC CALORIMETER
    BEDNARZ, G
    MILLIER, B
    WHITE, MA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08): : 3944 - 3952
  • [2] HIGH-RESOLUTION HIGH-SENSITIVITY MASS SPECTROMETERS
    MATSUDA, H
    MASS SPECTROMETRY REVIEWS, 1983, 2 (02) : 299 - 325
  • [3] HIGH-SENSITIVITY AND HIGH-RESOLUTION SPECTROSCOPY IN A RING CAVITY
    EZEKIEL, S
    HACKEL, RP
    KARE, J
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (05) : 647 - 648
  • [4] HIGH-SENSITIVITY PULSED HIGH-RESOLUTION CARS SPECTROMETER
    VOLKOV, SY
    KOZLOV, DN
    MALIKOV, MR
    OTLIVANCHIK, EA
    SMIRNOV, VV
    KVANTOVAYA ELEKTRONIKA, 1984, 11 (09): : 1851 - 1854
  • [5] INTEGRATED SILICON MAGNETOTRANSISTORS - HIGH-SENSITIVITY OR HIGH-RESOLUTION
    NATHAN, A
    BALTES, HP
    SENSORS AND ACTUATORS A-PHYSICAL, 1990, 22 (1-3) : 780 - 785
  • [6] MICROCOLUMN LC OF BIOLOGICAL COMPOUNDS - HIGH-RESOLUTION CAPABILITIES, MICROISOLATION, AND HIGH-SENSITIVITY MEASUREMENTS
    NOVOTNY, MV
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 101 - ANYL
  • [7] High-sensitivity and high-resolution methods for glycoprotein analysis
    Anumula, KR
    ANALYTICAL BIOCHEMISTRY, 2000, 283 (01) : 17 - 26
  • [8] NEW TECHNIQUES FOR HIGH-SENSITIVITY, HIGH-RESOLUTION SPECTROSCOPY
    EZEKIEL, S
    KVANTOVAYA ELEKTRONIKA, 1978, 5 (08): : 1649 - 1650
  • [9] High-resolution tangential absolute extreme ultraviolet arrays for radiated power density measurements on NSTX-U
    Delgado-Aparicio, L.
    Bell, R. E.
    Faust, I.
    Tritz, K.
    Diallo, A.
    Gerhardt, S. P.
    Kozub, T. A.
    LeBlanc, B. P.
    Stratton, B. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [10] HIGH-RESOLUTION AND HIGH-SENSITIVITY OPTICAL REFLECTION MEASUREMENTS USING WHITE-LIGHT INTERFEROMETRY
    CHOU, H
    SORIN, WV
    HEWLETT-PACKARD JOURNAL, 1993, 44 (01): : 52 - 59