THE RELIABILITY OF AUSCULTATORY MEASUREMENT OF ARTERIAL BLOOD-PRESSURE - A COMPARISON OF THE STANDARD AND A NEW METHODOLOGY

被引:27
|
作者
STOLT, M
SJONELL, G
ASTROM, H
HANSSON, L
机构
[1] The Department of Development of Primary Health Care, Stockholm, Stockholm County Council West
[2] Kvarters-akuten, Stockholm
[3] Department of Clinical Physiology, Thoracic Clinics, Karolinska Hospital, Stockholm
[4] Department of Medicine, University of Göteborg, Östra Hospital, Göteborg
关键词
Auscultatory method; Blood pressure measurment; Tricuff;
D O I
10.1093/ajh/3.9.697
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In 48 individuals with a wide range of arm circumferences blood pressure measured indirectly with two different cuffs was compared to direct intraarterial measurements. The two cuffs were a standard size cuff (12 X 35 cm) and a newly developed cuff, containing three rubber bags of different sizes, which automatically selects the appropriately sized bag in relation to arm circumference (Tricuff, Pressure Group AB, Sweden). The Tricuff correctly placed 42 of the 43 patients in the “normotensive” range, ie, diastolic blood pressure < 90 mm Hg, whereas the standard cuff put only 33 of 44 patients in this range (P <. 005). The discrepancy was not only due to the expected better performance in patients with obese arms, but also in the subgroup of patients with arms in the range 22 to 31 cm, in which group both cuffs would measure blood pressure with a 12 cm wide rubber bag. The number of correctly identified “normotensive” patients was noticeably higher with the Tricuff than with the standard cuff (30/31 v 25/32, P =. 053). The better specificity of the new cuff thus offers an improvement over the standard cuff. There are several potential clinical advantages of this, mainly that the risk of erroneously labelling normotensive individuals as hypertensive is reduced. © 1990 by the American Journal of Hypertension, Ltd.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 50 条
  • [1] A COMPARISON OF INTRA-ARTERIAL AND AUSCULTATORY BLOOD-PRESSURE READINGS
    CHYUN, DA
    HEART & LUNG, 1985, 14 (03): : 223 - 228
  • [2] CONFOUNDERS OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENT
    BAKER, RH
    ENDE, J
    JOURNAL OF GENERAL INTERNAL MEDICINE, 1995, 10 (04) : 223 - 231
  • [4] THE ACCURACY OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENT IN THE ELDERLY
    NIELSEN, PE
    ACTA MEDICA SCANDINAVICA, 1983, : 39 - 44
  • [5] AUSCULTATORY INDIRECT MEASUREMENT OF BLOOD-PRESSURE IN DOGS
    HARVEY, J
    FALSETTI, H
    COOPER, P
    DOWNING, D
    LABORATORY ANIMAL SCIENCE, 1983, 33 (04): : 370 - 372
  • [6] AUSCULTATORY BLOOD-PRESSURE MEASUREMENT - EFFECT OF PRESSURE ON THE HEAD OF THE STETHOSCOPE
    LONDE, S
    KLITZNER, TS
    WESTERN JOURNAL OF MEDICINE, 1984, 141 (02): : 193 - 195
  • [7] AUSCULTATORY MEASUREMENT OF BLOOD-PRESSURE PERFORMED BY DOCTOR ON DUTY
    NIELSEN, PE
    OXENBOLL, B
    ASTVAD, K
    GYNTELBERG, F
    ACTA MEDICA SCANDINAVICA, 1975, 198 (1-2): : 35 - 37
  • [8] PERIPHERAL VASCULAR EFFECTS ON AUSCULTATORY BLOOD-PRESSURE MEASUREMENT
    RABBANY, SY
    DRZEWIECKI, GM
    NOORDERGRAAF, A
    JOURNAL OF CLINICAL MONITORING, 1993, 9 (01): : 9 - 17
  • [9] ACCURACY OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENT WITH A LONG CUFF
    VANMONTFRANS, GA
    VANDERHOEVEN, GMA
    KAREMAKER, JM
    WIELING, W
    DUNNING, AJ
    BRITISH MEDICAL JOURNAL, 1987, 295 (6594): : 354 - 355
  • [10] MEASUREMENT OF ARTERIAL BLOOD-PRESSURE
    BEILIN, LJ
    JUELJENS.BE
    LANCET, 1972, 2 (7773): : 384 - &